To avoid any risk of fire electric shock or

 

injury, do not dismount the cellar.

 

 

To avoid any risk of fire, electric shock or 

injury,  do  not  immerse  the  power  cord, 
the  plug  or  the  device  in  water  or  any 
other liquid.

 

The power cable must not come in contact 

with sharp edges, hot parts or any source 
of heat.

 

If your cellar is damaged (major shock) or 

has  suffered  from  any  kind  of  incident 
(over  voltage  due  to  lightning,  flooding, 
fire), it may prove dangerous. Disconnect 
the  power  plug  and  have  the  device 
checked  by  an  approved  professional 
technician.

 

An electrical device must only be repaired 

by qualified personnel; unqualified repairs 
may lead to serious dangers for the user.

 

For  safety  reasons  do  not  use  an  electri- 

cal extension cord.

 

Always  remove  all  bottles  before  moving 

this cabinet.

 

Frost  formation  on  the  interior  evaporator 

wall and upper parts is a natural phenom- 
enon. Therefore, the cabinet should

 

be defrosted during normal cleaning or 
maintenance.

 

Please  note  that  changes  made  by  the 

owner  to  the  cabinet  construction  will 
cancel all warranty and product liability.

 

This  cellar  is  designed  to  conserve  exclu- 

sively wine. Do not store food!

 

This  wine  cellar  should  not  be  recessed 

or  built  in  an  endorsed  cabinet;  it’s  de- 
signed for freestanding installation only. 

Do  not  splash  or  spray  water  from  the 

hose on or in the cabinet. 

The  cabinet  shall  not  be  plugged  to  an 

ungrounded electrical power. 

The cabinet is supplied with a UL listed, 

3 wire power cord ready for connection 
to a 120V, 60Hz supply.

Summary of Contents for DIVA Revolution 195

Page 1: ...DIVA Revolution 195 User Guide...

Page 2: ...rope Avintage offers superior quality wine cabinets with a wide portfolio French Corner Cellars is the exclusive distributor of Avintage wine cabinets in the USA and Canada Already involved in wine ac...

Page 3: ...t to know your wine cooler 5 Before use 6 7 Installation and start up 8 Operation functions 9 11 Defrosting and cleaning 12 Technical data 13 14 Reversible door 15 22 Accessories 23 24 Customer Care a...

Page 4: ...imb inside Do not store explosive substances such as aerosol cans with a flammable propel lant in this cabinet Do not operate the cabinet in the presence of explosives and or flammable fumes Always ke...

Page 5: ...rious dangers for the user For safety reasons do not use an electri cal extension cord Always remove all bottles before moving this cabinet Frost formation on the interior evaporator wall and upper pa...

Page 6: ...USA 5 USA CA Get to know your wine cabinet Light Control panel Charcoal filter Wooden shelf Sealing strip Nameplate Kick plate Lock Adjustable feet...

Page 7: ...t the two caps supplied with the cabinet as shown on the picture Setting up It s important to have the cabinet leveled It can be adjusted by screwing or unscrewing the adjustable feet at the front of...

Page 8: ...USA 7 USA CA Max weight on the shelves fig 1 Max 85 kg 187 pounds fig 1...

Page 9: ...d avoid placing it in direct sunlight Ambient temperature The winter function will guaranty the wine cabinet to operate at an ambient temperature as low as 41 F Installation This wine cellar should no...

Page 10: ...the display indicate the temperature at the bottom of the cabinet The temperature indicator is equipped with a built in filter which simulates the actual temperature in the bottles Consequently the in...

Page 11: ...ing the compressor Door alarm When the door has been open for more than 2 minutes the door alarm is activated Child lock The thermostat is equipped with a child lock This device function is activated...

Page 12: ...emperature between the room and the desired temperature in the wine cabinet there might be a slight temperature gradient difference between the top and bottom The controls will maintain the set temper...

Page 13: ...with clean water and dry thoroughly The defrost water channel in which condensation from the evaporator runs is located at the bottom of the rear inside wall of the cabinet and must be kept clean Add...

Page 14: ...tion System Anti vibration system 1 active charcoal filter Constant hygrometry from 60 to 75 Temperature range from 40 F 5 C to 72 F 22 C Pushed air technology Temperature digital display 2 digital hy...

Page 15: ...abinet installation Power supply Grounded through 3 wire power supply cord 115V ac 60 Hz Single Phase Maximum fuse size 10Amps This cabinet is equipped with a three prong ANSI type 5 15P grounded plug...

Page 16: ...is done by a technician It is advised to have two persons to perform this operation Equipment needed 4 mm Allen key Flat headed screwdriver Torx 20 TX20 screwdriver 1 Open the door unscrew the two scr...

Page 17: ...d from the connector on the bottom cover pure black black white stripe wires Push the top release down to free the wire ends Note the pure black wire is and corresponds to the red wire on opposite sid...

Page 18: ...glass again and mount the brackets onto the plastic pro file in each end again Don t over tighten the screws Note The nut has to fit into the centre groove 9 The door has to be moved up from the hinge...

Page 19: ...pin and fit it on the opposite side Note The socket must also be moved 14 Turn the door so the glass side is down Note Place something between the glass and the other surface to prevent scratching the...

Page 20: ...em to the other side 17 Push the wires through the oblong hole and through the new hinge hole This can be a bit tricky so try to mount only one wire first 18 2 pictures Then tape the second wire end t...

Page 21: ...heat the strip all the way round using a hair dryer Then ease the strip slightly outwards so that it forms a tight seal against the cabinet Be careful not to heat the strip so much that it melts 20 D...

Page 22: ...hinge pin 24 and through the wire hole in the pla stic column 25 Remount the wires see under 6 and make sure that they are firmly secured 26 Push the door back in place over the hinge pin and pull th...

Page 23: ...Dismount the plastic caps on the top of the cabinet and mount them on opposite side 29 Make sure that the door is aligned with the cabinet before mounting the top hinge 30 Remount the bottom front cov...

Page 24: ...nd upright for approximately 24 hours This will reduce the possibility of a malfunction in the cooling system caused by handling during transportation Note If the door LEDs are not working but the top...

Page 25: ...20 66 x 17 3in 52 5 x 44 0cm Reference CLAVIP01 Sliding shelves Made of unscented oak to prevent any odor transmission to the wine Dimension 20 66 x 17 3in 52 5 x 44 0cm Reference CLAVIP06 Display she...

Page 26: ...ometer with digital display to clip on a shelf Reference THYG01 Note Switch F to C with the button on the back of the unit Filter Carbon filter to be placed in the wine cabinet Reference FCA 01 Labels...

Page 27: ...the defrost water channel and the drain hole on the rear wall of the cabinet Vibration or bothersome noise The cabinet is not levelled The cabinet is resting against other kitchen elements Containers...

Page 28: ...ill invalidate warranty and product liability and the cabinet cannot be used lawfully The approval stated on rating plate will also be invalidated Transport damage discovered by the buyer is primarily...

Page 29: ...fer station or dump Your municipality can direct you to a solid waste contractor for more information Other municipalities may require the refrigerant to be recovered from appliances before they will...

Page 30: ...without prior notice Please refer to our websites to obtain the most recent product specifications technical and warranty information www frenchcornercellars com 76 Clinton Street Saratoga Springs NY...

Reviews: