Jump to: Table of Content
2022/04/11
Page: 25
9
VCC (6..32V)
Power
Supply voltage does not carry an output voltage
–
thus if the device is powered via barrel connector, Pin
9 does not show the input voltage (internal diode). This is for security reason. If needed, Avisaro can
modify the device such that this pin can be used to power other devices.
5.6.6
WAGO - 2x CAN
Interface (“M4
33
24” / “C4
33
24”)
Connector
Interface
Pin
Signal
Direction
WAGO A
1
st
CAN
1
Ground
(Signal)
2
CAN-L
1
st
CAN Bus
3
CAN-H
1
st
CAN Bus
4
Future Use
(not
connected)
5
VCC (6..32V)
Power
6
GND
Power & Signal
WAGO B
2
nd
CAN
1
Ground
(Signal)
2
CAN-L
2
nd
CAN Bus
3
CAN-H
2
nd
CAN Bus
4
Future Use
(not
connected)
5
VCC (6..32V)
Power
6
GND
Power & Signal