background image

Jump to: Table of Content 

 

2022/04/11 

Page: 35 

 

6

 

C

ONFIGURATION

:

 

‘PC

 

C

OMPANION 

S

OFTWARE

 

6.1

 

H

OW TO CONFIGURE 

A

VISARO 

“S

ERIES 

4.0”

 PRODUCTS

 

The basic principle of how to configure the Avisaro “Series 4.0” products is:

 

1)

 

Download and install the “Avisaro PC Companion Software”.

 

2)

 

Connect the Avisaro device via USB cable. 

3)

 

Choose the correct COM port and click on “connect”. 

 

4)

 

The software presents all the settings you can make and guides you to avoid conflicting 
configurations. 

5)

 

Click on “save configuration” to store changes in the Avisaro device.

 

6)

 

Reboot the Avisaro Device so that the new configuration takes effect. 

Details are described further down in this document. 

6.2

 

 

C

ONCEPT OF OPERATION

 

The Avisaro 4.0 is divided into sections: 

 

Data are received through an “Interface” and then

 

forwarded to the “Data Processing” section. All 

formatting happens here and then data is forwarded to the “Data Endpoint”.

 

6.3

 

D

ETAILED DOCUMENTATION

 

This current document shows only selected 

parts of the full “

Avisaro PC Companion Software

 user 

manual. The motivation is to keep this document as compact as possible. 

Please find the extensive “Avisaro PC Companion Software” document in the support section of the 

Avisaro website:  

German: 

https://www.avisaro.de/de/40_Dokumentation.html

 

English: 

https://www.avisaro.com/en/40-ENG-Documentation.html

 

 

Summary of Contents for 4.0 Series

Page 1: ...ble of Content 2022 04 11 Page 1 Avisaro 4 0 Product Series Device User Manual Data Logger Gateways Complete Hardware Reference Manual RS232 CAN Bus RS485 0 10V 4 20mA Extensions Sensors Version Date...

Page 2: ...4 Enclosure 4 0 Sky with D Sub connector 9 3 5 Enclosure 4 0 Sky with WAGO connector 10 3 6 Enclosure 4 0 Sky with Ethernet and WAGO connector 11 3 7 Enclosure 4 0 Silver with screw type connector 12...

Page 3: ...23 5 6 1 Default CAN settings 23 5 6 2 Storage format and network packaging 23 5 6 3 Signal levels 24 5 6 4 Terminating resistor 24 5 6 5 D Sub Connector 1x CAN M43014 C43014 24 5 6 6 WAGO 2x CAN Int...

Page 4: ...he PC Companion Tool 37 7 Firmware and Configuration Update 38 7 1 Configuration Update 38 7 1 1 Introduction 38 7 1 2 Via PC Companion Software 38 7 1 3 Via USB Stick 38 7 2 Firmware Update 39 7 2 1...

Page 5: ...Jump to Table of Content 2022 04 11 Page 5...

Page 6: ...owing link Link https www avisaro de files Avisaro 40_Docu Avisaro Serie 4 0 User Manual pdf 2 4 LANGUAGE VERSIONS This document is available in English language only 2 5 OTHER DOCUMENTS Technical Use...

Page 7: ...eted documents are available Disadvantage is that in rare occasions a paragraph might have comments which do not fit to 100 in the place it is used 2 8 IMPRINT AND CONTACT This document is provided by...

Page 8: ...Red about 2sec than blue about 2sec Logger restarts This should not happen during normal operation Check power supply 1 On analog loggers e g 4 20mA and similar interfaces data are read continuously t...

Page 9: ...0 SKY WITH D SUB CONNECTOR Front with slot for USB stick Matches are shown just for size reference Reverse side shows D Sub connector for data and barrel connector for power The micro USB port is for...

Page 10: ...CONNECTOR Front with slot for USB stick Matches are shown just for size reference Reverse side shows the two WAGO connectors for data and power Optional a DIN rail fitting is available WAGO connector...

Page 11: ...ith slot for USB stick Matches are shown just for size reference Reverse side shows Ethernet RJ45 and WAGO connector for data and power The micro USB port is for configuration only Optional a DIN rail...

Page 12: ...f Content 2022 04 11 Page 12 3 7 ENCLOSURE 4 0 SILVER WITH SCREW TYPE CONNECTOR View into the enclosure with the lid unscrewed During normal operation the enclosure is sealed Optional a DIN rail fitti...

Page 13: ...desired format Windows Operating System does not allow to format sticks larger then 32 GByte with the FAT32 file system Usually sticks come pre formatted so you don t have to do anything If there is...

Page 14: ...emory the oldest files are deleted this is a useful setting for some applications 4 4 RECOMMENDED MEMORY STICKS It is difficult to recommend consumer grade USB sticks as detailed technical information...

Page 15: ...04 11 Page 15 Innodisk USB Drive 3SE 4 32 GB Industrial SLC Technology 4 4 2 Not recommended Manufacturer Model Picture Capacity Technology Remarks Verbatim Slider Store N Go 8 GB Consumer Stick failu...

Page 16: ...nly for configuration A stable regular operation is not guaranteed Use the regular power supply for normal operation A Micro USB cable is used As those cable are widely available this cable is not par...

Page 17: ...dely used barrel connector The matching plug has the following dimensions which are widely used and very much a standard Diameter outside 5 5 mm Pin inside 2 1 mm Shaft of 9 5 mm Polarity middle pin i...

Page 18: ...RS232 1 n c optional DCD 2 RxD Data in 3 TxD Data out 4 n c optional DTR 5 GND Power Signal 6 n c optional DSR 7 RTS Signal out 8 CTS Signal in 9 n c optional VCC 6 32V Power Supply voltage does not c...

Page 19: ...S out 3 RxD in 4 TxD out 5 VCC 6 32V Power 6 GND Power Signal WAGO B 1st RS232 1 CTS in 2 RTS out 3 RxD in 4 TxD out 5 VCC 6 32V Power 6 GND Power Signal Cables are connected with the WAGO 734 series...

Page 20: ...r easy cable connection from standard RS232 cable to WAGO including a power supply with a barrel connector Barrel connector for power supply The matching plug has the following dimensions which are wi...

Page 21: ...CE This is an industry standard RS485 bus connection 5 5 1 Default RS485 settings Those are the default settings Baudrate 9600 No of bits 8 Parity bits none Stop bits 1 Flow control none 5 5 2 Signal...

Page 22: ...A D RS485 Bus 5 VCC 6 32V Power 6 GND Power Signal Cables are connected with the WAGO 734 series connectors In most product configurations those adapters are shipped with the box Check the scope of de...

Page 23: ...7 n c 8 n c 5 6 CAN INTERFACE This is an industry standard CAN interface 5 6 1 Default CAN settings The baudrate needs to be configured using the Avisaro Companion Software The default baudrate is 25...

Page 24: ...not there is a 120 ohm terminating resistor depends on the product Product No Name 120 Ohm Termination M43076 C43076 CAN Silver Can be switched on off via configuration 5 6 5 D Sub Connector 1x CAN M4...

Page 25: ...needed Avisaro can modify the device such that this pin can be used to power other devices 5 6 6 WAGO 2x CAN Interface M43324 C43324 Connector Interface Pin Signal Direction WAGO A 1st CAN 1 Ground S...

Page 26: ...nnector WAGO 734 5 6 8 WAGO to D Sub Adapter There is a WAGO to D Sub adapter available product Z3012 This adapter allows for easy cable connection from standard CAN cable to WAGO including a power su...

Page 27: ...n c 7 CAN H 2nd CAN Bus 8 CAN L 2nd CAN Bus The 120 Ohm Line Termination resistor can be switched on off via configuration Thus no DIP switch needs to be used Refer to the PC Companion document in the...

Page 28: ...I O 4 GND 5 6 11 M12 male 1x CAN Interface Optional a M12 male connector is available Standard M12 connector male Connector Interface Pin Signal Direction M12 5 pol male 1st CAN 1 CAN H I O 2 CAN L I...

Page 29: ...differential current input with an internal resistance of 49 9 Ohms This allows to interface industrial standard 4 20mA sensors to the data logger 5 8 1 Default 20mA settings Input resistor 49 9 Ohm...

Page 30: ...ocument for details Connector Interface Pin Signal Direction WAGO A ADC3 ADC4 4 20mA 1 ADC3 mA 2 ADC3 mA 3 ADC4 mA 4 ADC4 mA 5 n c 6 Analog Reference GND Signal GND WAGO B ADC1 ADC2 4 20mA 1 ADC1 mA 2...

Page 31: ...04 11 Page 31 Connector Interface Pin Signal Direction Screw Type ADC3 ADC4 4 20mA 1 GND Power Signal 2 VCC 6 32V Power 3 ADC4 mA 4 ADC4 mA 5 ADC3 mA 6 ADC3 mA 7 Future Use not connected 8 Future Use...

Page 32: ...he range in reference to the isolated GND negative Pin Voltage 0V referenced to isolated GND positive Pin Voltage 15V referenced to isolated GND The input resistance is 1MOhm 5 9 2 Example Wiring sing...

Page 33: ...11 Page 33 5 9 4 WAGO 4x 0 10V Interface M49924 C49924 Connector Interface Pin Signal Direction WAGO A 1st 2nd 0 10V 1 1st 0 10V 2 1st 0 10V 3 2nd 0 10V 4 2nd 0 10V 5 not connected 6 Signal GND Signa...

Page 34: ...0 10V 2 3rd 0 10V 3 4th 0 10V 4 4th 0 10V 5 VCC 6 32V Power Supply 6 GND Power GND Cables are connected with the WAGO 734 series connectors In most product configurations those adapters are shipped wi...

Page 35: ...o Device so that the new configuration takes effect Details are described further down in this document 6 2 CONCEPT OF OPERATION The Avisaro 4 0 is divided into sections Data are received through an I...

Page 36: ...older with all files You can run the exe directly from there Windows warns the user before installing or using software downloaded from the Internet So if you click on Avisaro_40_Companion_v2 56_Setup...

Page 37: ...Avisaro Device It should light up green when clicked The baudrate setting for if connected through real RS22 can be ignored This setting is used only in special projects and not scope of this documen...

Page 38: ...most user friendly way to configure the Avisaro devices Use this as your preferred method See paragraph PC Companion Software for details on where to get and how to operate the software Find the compl...

Page 39: ...USB stick The SET PC_Headline_DataEndp TO RootDir Kapitel Companion Kapitel PC Headline DataEnd docx order is first the firmware update is performed second the configuration update is performed 7 2 FI...

Page 40: ...se broken devices needs to be send in to Avisaro for repair Background The configuration remains if not stated otherwise the same Thus all settings stay the same after a firmware update 7 2 3 Via PC C...

Page 41: ...but when the update is executed there is a window of 30 seconds which is sensitive to power failure Recommendations It is highly recommended to create a different user pointing to a different subdire...

Page 42: ...0 2018 11 02 15 12 51 147 C2 00000581 8 00 00 00 00 00 00 00 00 2018 11 02 15 12 51 447 C2 00000581 8 00 00 00 00 00 00 00 00 2018 11 02 15 12 52 163 C2 00000581 8 00 00 00 00 00 00 00 00 2018 11 02 1...

Page 43: ...e container CAN messages are mapped into a 28 byte long array This container format allows to hold variable length CAN messages while always maintaining the same container length It also adds a timest...

Page 44: ...ng Multiple CAN frame container could be packed into one UDP or TCP packet It is ensured that always a complete CAN container is packed 8 3 3 Networking Example Whireshark screenshot When used in netw...

Page 45: ...Jump to Table of Content 2022 04 11 Page 45 9 DECLARATIONS 9 1 EC EU DECLARATION OF CONFORMITY...

Page 46: ...of Content 2022 04 11 Page 46 10 CONTACT AND SUPPORT Please contact Avisaro if there are any questions Avisaro AG Grosser Kolonnenweg 18 E 30163 Hannover Germany Email support avisaro com End of this...

Reviews: