background image

contact the manufacturer. 

15. CAUTION: Please keep this device away from pets, pests, and children. 

16. CAUTION - Avoid potential allergic reactions, please avoid the front of scanner in 

direct contact to patient's wound. 

17. CAUTION: Please keep away from children and pets, because small parts may be 

inhaled or swallowed. 

18. CAUTION: This product should not be used on patients, who are unconscious or are 

not breathing spontaneously. 

19. The device is not suitable for use in an anaesthetic breathing system or a ventilator 

breathing system. 

 

 

Summary of Contents for NE10

Page 1: ...H Schiffgraben 41 30175 Hannover Germany AViTA Corporation 9F No 78 Sec 1 Kwang Fu Rd San Chung Dist New Taipei City 24158 Taiwan Importer Distributor INSTRUCTION MANUAL Please read this instruction manual carefully before using the device ...

Page 2: ...ion 1 Important Information before Use 3 Product Identification 5 Instruction for Use 6 Battery Supply 7 Change Air Filter 8 Cleaning and Disinfecting 9 Technical Specification 10 EMC Tables 11 Explanation of Symbols 13 ...

Page 3: ... device flows into the nebulizer container kit The air pressure forced the liquid through the nozzle where it is atomized against a plate within the container The device is equipped with a mouthpiece to easily delivery the medical aerosol Intended for Use NE 10 nebulizer is designed to aerosolize prescribed medication for inhalation by a patient in both the homecare and healthcare settings The neb...

Page 4: ...fied medical experts for home treatment 3 The user should be capable of understanding general operation of the content of instruction manual Intended Patient This product should not be used on patients who are unconscious or are not breathing spontaneously Durable Period Durable periods are as follows provided the product is used to nebulize 2 ml of medication twice a day for 7 5 minutes each time...

Page 5: ...evice just need to release the power button to turn off the device 7 The nebulizer is for inhaling medication for respiratory disorders only Do not use this device other than the intended purposes 8 During the use of the device should not hold his her breath 9 If you feel anything unusual when using the device stop and consult a doctor immediately 10 Do not use only water in the nebulizer for inha...

Page 6: ...t of scanner in direct contact to patient s wound 17 CAUTION Please keep away from children and pets because small parts may be inhaled or swallowed 18 CAUTION This product should not be used on patients who are unconscious or are not breathing spontaneously 19 The device is not suitable for use in an anaesthetic breathing system or a ventilator breathing system ...

Page 7: ...5 Product Identification 1 Mouthpiece 2 Inhalation Top 3 Medication Tank 4 Child Mask 5 Front Case 6 Adult Mask 7 Air Filter Cover Air filter inside 8 Power Key 9 Vaporizer Head 10 Bottom Case ...

Page 8: ...s securely attached to the inhalation top 4 Rotate the inhalation top clockwise until the alignment mark on it and the alignment mark on the medication tank are aligned and they click in place 5 Attach the mask mouthpiece or optional nosepiece to the nebulizer kit tightly 6 Switch on the power button continuously and the nebulization is generated 7 When the treatment is complete release the power ...

Page 9: ...s BLUE while charging the batter 4 When the battery is full the charge indicator light shows GREEN Please plug out the charger PRECAUTION 1 DO NOT USE THE NEBULIZER WHILE CHARGING THE NEBULIZER CANNOT OPERATE WHILE CHARGING WE DO NOT TAKE RESPONSIBILITY FOR USING CHARGER OR ADAPTER INAPPROPRIATELY 2 To ensure safe using the adapter and electronic equipment with USB port should meet the electrical ...

Page 10: ... 1 Use only AViTA air filters designed for this device Do not operate without air filter 2 Do not wash or clean the air filter If the air filter becomes wet replace it Damp air filters can cause blockages 3 There s no front or back orientation for the air filters 4 Check the air filters are clean and free of dust before inserting them ...

Page 11: ...le parts 1 Compressor Soft dry cloth and non abrasive cleaners for the outer case of the compressor 2 Air filter Do not wash or clean the air filter If the air filter becomes wet replace it Damp air filters can cause blockages CAUTION Always wash the vaporizer head after each use Do not use a brush or pin to clean the vaporizer head When disinfecting the parts by boiling be sure to boil them in pl...

Page 12: ... 5 W x 54 H mm 8 Weight 163g 9 Operating conditions 10 C to 35 C 41 95 30 to 85 relative humidity non condensing Atmospheric pressure 700 1060 hPa 10 Storage conditions 20 C to 60 C 4 140 up to 95 relative humidity non condensing Atmospheric pressure 700 1060 hPa 11 Battery Operation Time About 30 minutes Depends on different brand of batteries 12 Lifetime 3 years 13 Battery Shelf Life 3 years 15 ...

Page 13: ...suitable for use in the mentioned environments when directly connected to the Public Mains Network b The test is not applicable in this environment unless the ME EQUIPMENT and ME SYSTEM used will be connected to the PUBLIC MAINS NETWORK and the power input is otherwise within the scope of the Basic EMC standard Guidance and manufacturer s declaration Electromagnetic immunity Enclosure port Phenome...

Page 14: ...m c 50 Hz or 60 Hz a The equipment is suitable for use in Home Health Environments and Professional Health Care Environments limited to patient rooms and respiratory treatment facilities in hospital or clinics The more restrictive IMMUNITY acceptance limits have been considered and applied b Before modulation is applied c This test level assumes a minimum distance of at least 15 cm between the ME ...

Page 15: ...M Batch code YYMMWWWW WWWW working sheet no Serial number YYMWWWXXXXX WWW working sheet no XXXXX serial no Keep dry Temperature limit Humidity limitation Atmospheric pressure limitation Caution Consult the instruction for use Disposal information Should you wish to dispose of the article do so in accordance with current regulations Details are available from your local authority WEEE 2012 19 EU Di...

Page 16: ...sification type BF This product meets the basic safety and essential performance requirements indicated in the IP22 conditioning test protection against solid foreign objects of 12 5mm and greater and against vertically falling water drops when enclosure tiled up to 15 The empty completely flat batteries must be disposed of through specially designated collection boxes recycling points or electron...

Page 17: ...15 NE10P 22287AV Jun 27 2022 ...

Reviews: