background image

subject's forehead or object at the distance indicated by the device. 

11.  Accurate and Reliable 
12.  User Friendly 
 

Due to our unique design of the measuring software, users don't 
need to have special skill to operate this device. 

13.  Instant Measurement 
 

By using our unique technology, users can get their precise body 
temperature instantly and accurate. 

14.  Handicapped persons and children need assistance by another 

person to use the device. 

15. 

CAUTION

: Please keep this device away from pets, pests, and 

children. 

16. 

CAUTION

: Please keep away from children and pets, because 

small parts may be inhaled or swallowed. 

17. If any serious incident that has occurred in relation to the device 

should be reported to the manufacturer and the competent 
authority of the Member State in which the user is established. 

18. If you would require any assistance during setting up, using or 

maintaining, please contact the manufacturer. 

19. Avoid using the device near an operating cell phone or microwave 

oven. 

 

 

 

Summary of Contents for NT22B

Page 1: ...TOUCH FREE Infrared Thermometer NT22B EN INSTRUCTION MANUAL Please read this instruction manual carefully before using your forehead thermometer ...

Page 2: ...Switching between 4 Kinds of Measuring Mode 7 Tips for Measuring Human Temperature 8 Measuring Human Temperature 9 Measuring Object Liquid Temperature 11 Memory Function 12 Operating the Bluetooth function 13 FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT 14 Cleaning and Disinfecting 15 Error Codes 16 Technical Specification 17 EMC Tables 18 Explanation of Symbols 20 ...

Page 3: ...ed persons and children need assistance by another person to use the device 1 2 in 1 thermometer Human Body Object 2 Fever Indication Human Body Mode only 3 C F Switch able Function 4 Multi memory Recall 5 One second Reading 6 Power Saving Auto Power Off Auto power off after idling to ensure battery life 7 Warning indication low battery symbol and Lo Hi symbol indicating out of measuring range 8 L...

Page 4: ... assistance by another person to use the device 15 CAUTION Please keep this device away from pets pests and children 16 CAUTION Please keep away from children and pets because small parts may be inhaled or swallowed 17 If any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user is estab...

Page 5: ...void extreme shock or dropping the device 8 Before the measurement patients and thermometer should stay in steady state room condition for at least 30 minutes 9 Avoid measuring temperature in 30 minutes after exercise bathing or returning from outdoor 10 To protect the environment dispose of empty batteries at appropriate collection sites according to national or local regulations 11 Please use th...

Page 6: ...4 Product Identification 1 Memory Button 2 Mode Button 3 Battery Cover 4 Display LCD 5 Measure Button 6 Measurement Sensor 7 Distance Detection Sensor ...

Page 7: ...cess Night Mode Mute Mode Human Mode Object Mode Degree of measurement Celsius Scale Fahrenheit Scale Low battery indicator Frowning Face temperature is equal or higher than 38 C Smiling Face temperature is lower than 38 C Memory Symbol and sets of records ...

Page 8: ...s according to the instructions Replacing the Battery 1 Gently slide the battery cover back 2 Carefully remove the old batteries and properly discard 3 Insert new batteries Two 1 5V alkaline AAA LR03 Size according to the proper polarity 4 Slide the battery cover back on NOTE Battery operated 1 Please properly dispose of the batteries away from small children and heat 2 It is recommended to remove...

Page 9: ...f Measuring Mode 1 Under power on status you can press the Mode Button to switch different measuring mode There are 4 kinds of mode which including Human Object Human Night and Object Night Mode in order 2 The beep sounds will be off mute when your choice in Human Night Mode and Object Night Mode and the Moon symbol will appears on the LCD in both Night Modes NOTE Each press will comes with a beep...

Page 10: ...emperature readings from sites on the body other than the forehead may produce inaccurate results The patient should remain still while the reading is being taken Readings taken while asleep should not be compared directly to readings taken while awake as body temperature while asleep is typically lower Do not take body temperature readings within 30 minutes of being outdoors exercising or bathing...

Page 11: ... If the patient s skin is covered with hair sweat or dirt clean the area and wait 10 minutes before taking a measurement Ensure that the thermometer is held firmly during measurement and that the patient does not move until the measurement is complete Movement can impact the measurement 3 Position the thermometer under 3cm around 1 inch from the center of the patient s forehead with the sensor aim...

Page 12: ...ort beep means this temperature reading has been completed and accompany with a back light 7 If the temperature measurement is below 38 C a Smiling Face will appear next to the reading If the reading is 38 C or above a Frowning Face will display and the LED light up to alert 8 After about 60 seconds after use the thermometer will automatically beep and shut off Fever Alarm Only in Human Mode and H...

Page 13: ...he Object symbol will be on the display To alternate between modes press and release the Human Object Mode Button until you see the desired measurement symbol on the display 3 Position the thermometer under 3cm around 1 inches from the object 4 Release the Measure Button and the temperature reading will be displayed 5 After use the thermometer will automatically beep and shut off after idling ...

Page 14: ...he symbol or symbol will appear with each measurement stored in memory to indicate whether a person or object temperature was taken 3 Each press of the same button recalls a previous measurement Memory Deletion 1 Under power on status you may hold press the Memory button to delete all the readings The LCD shows with one beep sound to indicate that all memories are cleared 2 Remove batteries memory...

Page 15: ...mart phone for how to activate the Bluetooth function Set Up Process 1 Download an app which supports Bluetooth 4 0 from the iTune App Store 2 Enable Bluetooth on your mobile device 3 Open the app 4 Turn on the device The Green LED light will be flashing 5 The app should automatically detect your device Tap the device that is showed in the device list The Green LED light off 6 Your device is now s...

Page 16: ... to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CAUTION Any changes or modifications not expressly...

Page 17: ...surement sensor with an alcohol swab before and after each measurement Thermometer Use a soft dry cloth to clean thermometer body Never use abrasive cleaning agents thinners or benzene for cleaning Do not scratch the surface of the probe lens or the display Do not expose the thermometer to extreme temperatures humidity direct sunlight or shock ...

Page 18: ...e 100 C 212 0 F Operate the thermometer only between the specified temperature ranges If necessary clean the sensor tip In the event of a repeated error message contact your retailer or Customer Services The temperature measured is lower than measurement range Human mode 34 C 93 2 F Object mode 0 C 32 0 F The operating temperature is not in the range 15 C 40 C 59 F 104 F Operate the thermometer on...

Page 19: ...y 10 sets Dimensions approx 142mm 42mm 42 4mm W D H Operation Distance 3 cm Frequency 2402 2480GHz Output power range 4dBm Battery Operation Time about 90 minutes Depends on different brand of batteries Typical Service Life 3 years Reference body site Ear temperature For Customer Service It is recommended that the accuracy should be checked by manufacture every 1 years To obtain the service please...

Page 20: ...considered and applied The equipment is suitable for use in the mentioned environments when directly connected to the Public Mains Network b The test is not applicable in this environment unless the ME EQUIPMENT and ME SYSTEM used will be connected to the PUBLIC MAINS NETWORK and the power input is otherwise within the scope of the Basic EMC standard Guidance and manufacturer s declaration Electro...

Page 21: ...ncy magnetic fields IEC 61000 4 8 30 A m c 50 Hz or 60 Hz a The equipment is suitable for use in Home Health Environments and Professional Health Care Environments limited to patient rooms and respiratory treatment facilities in hospital or clinics The more restrictive IMMUNITY acceptance limits have been considered and applied b Before modulation is applied c This test level assumes a minimum dis...

Page 22: ... denotes the compliance of Regulation EU 2017 745 Medical Device Manufacturer Authorized representative in the European Community Date of manufacture YYYY Batch code LOT WWWXXXXX LOT Lot Number WWW working sheet XXXXX serial no Serial number SN YYMWWWXXXXX YY year M month WWW working sheet XXXXX serial no Keep dry ...

Page 23: ...able from your local authority WEEE 2012 19 EU Directives RoHS This product fulfilling the requirements of the RoHS Directive 2011 65 EU REACH This product fulfilling the requirements of the REACH Directive EC 1907 2006 and its amendments do not contain Substances of Very High Concern in concentration above the limit of 0 1 No substance s is are present in the parts of the product above the concen...

Page 24: ...objects of 12 5mm and greater and against vertically falling water drops when enclosure tiled up to 15 The empty completely flat batteries must be disposed of through specially designated collection boxes recycling points or electronics retailers You are legally required to dispose of the batteries Importer Distributor Model Number Country of Manufacturer Unique Device Identifier ...

Page 25: ...23 MDSS GmbH Schiffgraben 41 30175 Hannover Germany AViTA Corporation 9F No 78 Sec 1 Kwang Fu Rd San Chung Dist New Taipei City Taiwan R O C Made in P R C 72 N22MNEU AV11 2021 11 05 ...

Reviews: