39
© 2008 Directed Electronics. All rights reserved.
4 CRANK TIME—
0.6
/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0 Sec-
onds:
If Feature 2 is programmed to the voltage sense setting, the crank
time must be set to the appropriate duration. The default setting is 0.6
second. If a different crank time is desired, press the Channel Two
button to advance through the LED Off settings. The unit will flash the
LED to indicate which time is selected. Once the 4.0 second setting is
reached the next press of the Channel Two button will reset the system
to the shortest setting.
5 ACTIVATION PULSE COUNT—
1
/2/3 PULSES:
This feature allows the number of pulses to activate the remote start
feature to be changed from 1, 2, or 3 pulses. The pulse count pro-
grammed to start the vehicle will also be the same required to shut
down the remote start.
6 2nd—
IGNITION
/ACCESSORY OUTPUT:
This will allow the PINK/WHITE to be used as a 2
nd
ignition or a
2
nd
accessory.
7 ACCESSORY STATE DURING WAIT-TO-START—
OFF
/ON:
This will allow the programming of the accessory wire during the wait-
to-start period of a diesel motor. When ON the accessory comes on
when the wait-to-start output is activated and stays on, dropping out
during crank and returning once the car has started. When OFF the
accessory will activate as a normal accessory.
8 2nd STATUS OUTPUT—
NORMAL
/LATCHED/PULSED:
If programmed to status mode, this output will turn on when the remote
start is activated. In this mode the output can be programmed to a
latched or a pulsed output. The pulsed output turns the defogger ON.