Troubleshooting
•
The starter cranks for six seconds but does not start.
Either the wrong ignition wire is being energized, the system’s ignition
and accessory wires have been connected backwards, or the vehicle
has two ignition circuits. Try activating the unit with the ignition key in
the “run” position. If the vehicle then runs normally, retest your ignition
system.
•
The climate control system does not work while the unit is operat-
ing the vehicle.
Either the wrong accessory wire is being energized or more than one
ignition or accessory wire must be energized in order to operate the
climate control system.
•
The remote start will not activate.
1. Check harnesses and connections. Make sure the harnesses are
fully plugged into the remote start module. Make sure there are
good connections to the vehicle wiring.
2. Check voltage and fuses. Also make sure that the ground wire is
going to a chassis ground and not to something under the dash.
3. Check diagnostics. The diagnostics will tell you which shutdown is
active or not connected.
•
The remote start will activate but the starter never engages.
1. Check for voltage on the purple starter wire two seconds after the
remote start becomes active. If there is voltage present, skip to
Step 4. If there is not voltage present, advance to Step 2.
2. Check the 30A fuses.
3. Make sure the purple starter wire is connected on the starter side
of the optional starter kill relay.