13
© 2009 Directed Electronics. All rights reserved.
➤
Primary harness (H1), 12-pin connector
H1/1
RED/WHITE
(-) 200mA AUX TRUNK RELEASE OUTPUT
H1/2
RED
(+) CONSTANT POWER INPUT
H1/3
BROWN
(+) SIREN OUTPUT
H1/4
EMPTY
NOT USED
H1/5
BLACK
(-) CHASSIS GROUND INPUT
H1/6
VIOLET
(+) DOOR TRIGGER INPUT, ZONE 3
H1/7
BLUE
(-) INSTANT TRIGGER INPUT, ZONE 1
H1/8
GREEN
(-) DOOR TRIGGER INPUT, ZONE 3
H1/9
BLACK/WHITE
(-) 200mA DOMELIGHT SUPERVISION OUTPUT
H1/10
WHITE/BLUE
(-) REMOTE START ACTIVATION INPUT
H1/11
WHITE
(+)/(-) SELECTABLE LIGHT FLASH OUTPUT
H1/12
ORANGE
(-) 500mA GROUND WHEN ARMED OUTPUT
➤
Auxiliary harness (H2), 6-pin connector
H2/1
LIGHT BLUE
(-) 200mA SECOND UNLOCK OUTPUT
H2/2
WHITE/BLACK
(-) 200mA AUX 3 OUTPUT
H2/3
VIOLET/BLACK
(-) 200mA AUX 2 OUTPUT
H2/4
GREEN/WHITE
(-) 200mA FACTORY ALARM REARM OUTPUT
H2/5
GRAY/BLACK
(-) WAIT-TO-START INPUT
H2/6
LIGHT GREEN/
BLACK
(-) 200mA FACTORY ALARM DISARM OUTPUT
➤
Door lock harness, 3-pin connector
1
LIGHT BLUE
(-) UNLOCK (+) LOCK OUTPUT
2
EMPTY
NOT USED
3