background image

17

No.

Faults

Causes

Solutions

1

Power-up Failure

Under-voltage 

Protection

Charge the aviva L780.

Abnormal Load 

Protection

Remove the loads and recharge 

the aviva L780. If the problem 

can not be solved, ask for 

customer service.

Product Failure

Contact aviva Customer Service.

2

Charger Fault

Unmatched 

Charger

Only use the authorized charger.

Charger Failure

Contact aviva Customer Service.

Abnormal 

Power Supply or 

Connection

Re-connect the charger. If the 

problem cannot be solved, 

contact aviva Customer Service.

3

Solar Panel

Charging Fault

Over-voltage

Use the recommended solar 

panel.

Weak Sunlight

Charge in location with more 

direct sunlight.

Solar Panel Failure

Contact aviva Customer Service.

Abnormal Wiring-

harness Connection

Re-connect the wiring-harness. 

If the problem can not be solved, 

contact your local dealer to 

replace the solar panel.

4

DC / AC

Output Fault

Battery Under-

voltage Protection

Charge the aviva L780.

Discharge Over-

current Protection

Check and ensure the power 

loads are within the allowed 

range.

Over-temperature

Protection

Turn off the aviva L780 and 

restart after cooling down.

Product Failure

Contact aviva Customer Service.

5

Abnormal Icon

Display

Abnormal Loads

Remove the loads.

Hardware Fault

Contact aviva Customer Service.

LCD Screen Failure

Contact aviva Customer Service.

6

LCD Screen Fault

LCD Screen Failure

Contact aviva Customer Service.

TROUBLESHOOTING

Summary of Contents for L780

Page 1: ...USER MANUAL Model L780 Part No PR750NAL780 Portable Power Station ...

Page 2: ...2 aviva Customer Service Email support avivapower com Visit www avivapower com If in need of service please contact aviva Customer Service Do not return this unit to the store ...

Page 3: ...duct and its use You can use this product at home and away wherever life takes you Many people will use the aviva L780 as a central power source at home or wherever they need portable power such as off grid or for emergency back up power Save this User Manual Long Term Maintenance Fully charge the power station unit prior to long term storage Check and charge the power station unit at least once e...

Page 4: ... OF CONTENTS Specifications Product tour functions General information How to charge the product Lighting Recharging Warning states Disposal Troubleshooting Attention Safety and maintenance Warranty statement ...

Page 5: ...charge once every 3 6 Months Wattage Compatiblity 500 W continuous Battery Management System BMS Over voltage protection low voltage protection over temperature protection short circuit protection over current protection Input Ports DC Charging 2 pin AC adaptor Solar Port Anderson port PA45 14V 25V maximum power up to 180W Output Ports USB C Two 2 USB C PD output ports 65W supports 5V 9V 12V 15V 2...

Page 6: ...ode with SOS mode Display Panel LED display info relates watt input output battery status Color Two tone gray black Cabinet Durable ABS polycarbonate shell Unit Weight 16 5 lbs 7 5 kgs Unit Dimensions 13 7 6 3 11 2 in 35 16 29 cm Retail Box Weight 20 lbs 9 06 kgs Operating Use Temperature 14 113 F 10 45 C Recharging Temperature 32 to 113 F 0 45 C AC Charger Included 110V 60Hz 13V 250VA includes po...

Page 7: ...10 hrs with engine on Solar Panel 100 W 17 hrs Optional Accessories Portable solar panel Included in the Box Power station AC charger with power cable user manual USER MANUAL Model L780 Part No PR750NAL780 Portable Power Station 12V 3W Lighting Stereo PSP Camera Smart Phone Tablet Laptop 60W Fan 32 TV Mini Bar 230h 500X 90X 160X 70X 17X 8X 12h 7h 15h ...

Page 8: ...UNCTIONS 1 ON OFF Power Switch 2 LCD Screen 3 AC Adapter Input 4 Solar Charging Input 5 USB Outputs 6 12V DC Outputs 7 DC Auto Output 8 AC Output Button 9 AC Output Indicator 10 AC Outputs 11 Cooling Fan 12 Light 13 Light Button 14 Handle ...

Page 9: ... Indicator Output USB in use 12V DC in use 12V DC Auto Output in use AC Power is on Remain rotating when DC in use or AC is on Input In Solar Charging In AC Charging In the Charging Process LCD Screen Guide 12V DC Auto Output ...

Page 10: ...iva L780 it will start initial self checking During the process all the icons on the LCD screen will be activated The LCD screen will turn to normal display if all functions are normal Power Off When usage is complete power off the unit by following these steps 1 Remove all the connected cables and loads 2 Press to turn off the AC output and the LED indicator will be off 3 Long press the AC button...

Page 11: ... output button on off should not be less than 5 seconds Using 5V Output USB outputs can be used directly to charge your devices When the aviva L780 detects the load the USB icon on the LCD screen will be activated The aviva L780 has both USB A and Type C ports that can recharge a variety of devices Please see the technical specification for output parameters in Page 8 Note different USB ports are ...

Page 12: ...n on the LCD screen will be activated Our product has two separate 12V DC outputs with the same output power Using 12V DC Auto Output 12V DC Auto Output can be used directly to charge your devices When the aviva L780 detects the load the 12V DC Auto Output icon on the LCD screen will be activated The maximum output power is 120W ...

Page 13: ...s 5 lighting modes High bright 100 power Normal 50 power Energy saving 25 power Emergency flash and SOS Press the light button firmly to turn on off the light and press gently to shift between different modes SO S LIGHTING ...

Page 14: ...mprove efficiency Following full re charge times are based on ideal conditions 40W Input 60W Input 80W Input 100W Input 120W Input aviva L780 33hrs 42hrs 20hrs 25hrs 17hrs 20hrs 13hrs 17hrs 10hrs 12hrs The above data is for reference only The data will fluctuate depending on the environment use method and other factors Solar Charging HOW TO RECHARGE Wall Charging ...

Page 15: ...conds and buzzing stops after 30 seconds Warning and solar input icons flash AC charging failure caused by one of any following reasons 1 Charging voltage is out of allowable range 2 Charging current is beyond the max allowable value 3 Solar charging port is over temperature 7 Warning and charger icons flash Charging failure caused by one of any following reasons 1 Charging voltage is out of allow...

Page 16: ...lowing reasons 1 Overload 2 Short circuit 3 Over voltage 12 Warning and Battery icons flash power icon normally displays Communication between battery voltage acquisition board and display board is interrupted 13 Warning Battery and Power icons flash power icon displays current power Battery alarm due to over temperature protection or low temperature protection DISPOSAL The aviva L780 must not be ...

Page 17: ...ight Charge in location with more direct sunlight Solar Panel Failure Contact aviva Customer Service Abnormal Wiring harness Connection Re connect the wiring harness If the problem can not be solved contact your local dealer to replace the solar panel 4 DC AC Output Fault Battery Under voltage Protection Charge the aviva L780 Discharge Over current Protection Check and ensure the power loads are w...

Page 18: ...r charger Use the aviva L780 between 20 90 battery level to achieve longer service life and better performance Keep away from heat source fire inflammable gas or liquid and do not expose to the sun for long time Recharge or use it at least once every four months for a longer service life Keep away from children or pets Not allowed aboard planes Unauthorized disassembly is forbidden Violation may c...

Page 19: ...r or under intense heat or fire The unit is not waterproof avoid water and other liquids Store the unit in a cool dry place and avoid humid dusty environments Do not disassemble this device without permission Do not drop nor place heavy objects on or strike the product with force Do not cover this product with objects such as towels or clothing during use Do not charge longer than the time require...

Page 20: ...mer purchaser The sales receipt from the first consumer purchase or other reasonable documentary proof is required in order to establish the start date of the warranty period Remedy aviva Power will repair or replace at aviva s option any aviva product that fails to operate during the applicable warranty period due to defect in workmanship or material If a valid claim is made during the applicable...

Page 21: ...RMA number and will provide you with return instructions You must properly package the product clearly marking the RMA number on the package and including proof of your purchase date with the product We will process your return and send your repaired or replacement product to you in North America For product purchased or being shipped outside of North America please contact the local distributor f...

Page 22: ...ABILITY OR UNDER ANY OTHER THEORY OF LIABILITY EXCEED THE AMOUNT PAID BY YOU FOR THE AVIVA PRODUCT Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you ...

Page 23: ...statements accompanying such products and services aviva shall not be liable for technical or editorial errors or omissions contained herein First Edition 120120 Document Part Number L780UMV1 IMPORTANT NOTICE The pictures in this manual are for reference only If some pictures do not match the actual product the actual product shall prevail The AC power socket and AC voltage and frequency of this p...

Page 24: ...www avivapower com ...

Reviews: