Adjust the sensors
The lower sensor initiates the events that get ready for the next pick, so the
location of this sensor has a lot of margin. The upper sensor needs to be
placed in a position that will activate the Compu-Dobby solenoids after the
metal insert that catches the cable balls has moved above the balls.
1)
Place the lower sensor 2" above the bottom of the cylinder.
2)
For the upper sensor, watch the dobby cables and slide plate
interact while making the sensor adjustment.
Note:
Be careful not to over-tighten the sensor straps. Snug the screw
only enough to keep the sensor from sliding down the cylinder
during operation.