iDirect Modem
AvL Technologies
| Proprietary – Content is Subject to Change without Notice
11
PlateauPeaking
peaking routines
Cross Pattern
Coarse Azimuth
Velocity
4
Float
.02 to 1
0.25
Azimuth velocity in
degrees/sec for coarse peaking
Cross Pattern
Coarse Elevation
Velocity
4
Float
.02 to 1
0.25
Elevation velocity in
degrees/sec for coarse peaking
Cross Pattern
Coarse Peaking
Height
4
Float
.25 to 5
1
Height in degrees to scan
during a coarse cross pattern
peaking function
Cross Pattern
Coarse Peaking
Width
4
Float
.25 to 5
2
Width in degrees to scan
during a coarse cross pattern
peaking function
Cross Pattern
Coarse Signal
Tolerance
1
Float
0 to 1000
10
Signal degradation amount
before a scan stops
Fine Peaking
Mode
4
Choice
None,
CrossPattern,
StepPatten,
PlateauPeaking
StepPattern
Selection of the peaking
method to use for fine peaking
routines
Polarization
Peaking Enabled
4
Choice
Yes, No
No
If set to yes then pol will be
peaked after fine peaking
Scan Azimuth
Velocity
4
Float
0.1 to 60
0.5
Azimuth scanning maximum
velocity used in scanning
movements
Scan Elevation
Velocity
4
Float
0.1 to 60
2
Elevation scanning maximum
velocity used in scanning
movements
Step Pattern
Fine Azimuth
Velocity
4
Float
0.02 to 5
0.15
Azimuth velocity in
degrees/sec for fine peaking
Step Pattern
Fine Elevation
Velocity
4
Float
0.02 to 5
0.15
Elevation velocity in
degrees/sec for fine peaking
Step Pattern
Fine Peaking
Azimuth Step
4
Float
0.01 to 5
1
Width in degrees to scan
during a fine step pattern
peaking function
Step Pattern
Fine Peaking
Elevation Step
4
Float
0.01 to 5
1
Height in degrees to scan
during a fine step pattern
peaking function