Trouble-shooting
Industrial Dobby Loom User's Manual
Page | 52
Basic Troubleshooting Tips
B
ASIC
T
ROUBLESHOOTING
T
IPS
Anytime you are troubleshooting a problem on the loom, stop the loom and
put it in Manual mode. The following tips indicate what you should check
when you are seeing a given problem. Following this section is information
on how to deal with specific issues.
Shuttle Doesn't Fire
Check that shuttle has boxed completely
Check if the shuttle sensor is out of adjustment
If more than one shuttle is presenting:
A shuttle may have been placed in the wrong box
A drafting error may have been made; check the program
Shuttle Won't
Stay On Race
The bobbin is improperly wound
A knot in the weft is catching on the shuttle tensioner
The Bobbin is nearly empty and out of balance
The Shuttle boxes need to be adjusted
Shuttle Doesn't Box Completely
Insufficient air pressure
The binder (shuttle brake) is too tight
The shuttle boxes need to be adjusted
Knotted weft yarn may have hung in the tensioner and
impeded
shuttle travel; usually, but not always, it stops or
derails shuttle
Loom Fires on
Empty Box
Shuttle sensor out of adjustment
Loom Stops -- Red Light Is On
Empty bobbin
Two shuttles presenting
Loom Stops -- Green Light Is On
Sensors out of adjustment