AV-C310-ILA& AV-C410
Solar Powered ICAO Low Intensity Obstruction Light Type A
Latest products and information available at www.avlite.com
21
Designed to be almost maintenance-free, the AV-C310-ILA and AV-C410-ILAB require minimal attention,
though the following maintenance and servicing information is provided to help ensure the life of your
Avlite Systems product.
1. Cleaning Solar Panels- occasional cleaning of the solar panels may be required. Using a cloth and
warm soapy water, wipe off any foreign matter before rinsing the panels with fresh water.
2. Battery Check- inspection of batteries should be performed every three years (minimum) to ensure that
the charger, battery and ancillary electronics are functioning correctly. Using a voltage meter, check
that the battery voltage is at least 12 volts under 100MA load, and ensure all terminals are clear of
foreign matter.
3. O-Ring Check- inspect the condition of the o-ring for damage, wear or if it is brittle, and replace if
necessary. The o-ring should be a rubber texture to ensure a complete and even seal.
The AV-C310-ILA and AV-C410-ILAB have an internal battery compartment, which provides the user with
the ability to change the battery after years of operation.
1. Remove the four socket-head screws on the top lens assembly and separate the
AV-C310/
AV-
C410-ILAB lens assembly from the body/base section.
2. Remove 2 x M4 cap screws & washers from the top of the chassis.
3. Separate the light head and battery via the 4Pin connector.
4. Lift the upper battery bracket out of the AV-C310/AV-C410.
5. Remove the old battery from the chassis.
6. Contact Avlite if you require a battery.
7. Discard old battery in a safe manner.
8. Reconnect the new battery.
9. Place battery back inside light body, and position the upper battery bracket in the top of the chassis.
10. Secure using 2 x M4 cap screws & washers.
11. Feed all wiring back inside light body, and make sure the o-ring is properly placed at the top of the light
body.
12. Place the top lens assembly back onto the light body and replace 4 socket head screws. Half tighten
all 4 socket head screws, and then fully tighten each socket head screw to ensure an even seal.
Recommended torque settings for Fitment of Light Heads to Solar Base units using the 4 Hex Bolts
supplied. It is recommended that the bolts for holding the light heads to the Solar Base units have a
torque setting applied of 3Nm for a satisfactory seal.
Applying a higher Torque setting is not recommended and may void warranty. If in doubt, please
contact your local Avlite representative.
13. To test place dark cover (towel or jacket) on top of light for a minimum 30 seconds to activate the light.
Care must be taken to observe the polarity of each wire before they are connected.
To ensure waterproofing of the unit, make sure that there is an even seal.
Maintenance & Servicing
Replacing the battery