25
Problem
Remedy
Light will not activate.
• Ensure light is in darkness.
• Wait at least 60 seconds for the program to initialise in
darkness.
• Ensure switch setting is on a valid code (not unused flash code).
• Ensure battery terminals are properly connected.
• Ensure battery voltage is above 12volts.
• Check the Status LED’s on the base of the PCB to determine
what type of fault the light is activating.
Light will not operate for the
entire night.
• Expose light to direct sunlight and monitor operation for several
days.
Avlite products typically require 2.5 hours of direct sunlight
per day to retain full autonomy. From a discharged state, the
light may require several days of operational conditions to ‘cycle’
up to full autonomy.
• Ensure solar module is clean and not covered by shading during
the day.
All AV-C310-ILA and AV-C410-ILAB Lights are fitted with two Indicator LED’s. These are positioned on
the edge of the board, near the Flash Code Rotary Switches. Use the table below to help determine
operational status.
Yellow Status LED
Condition
Off
Daylight, Standby
Quick Flashing
Day to Night transition
2 Quick Flashes
Night Operation, Not Synchronized
1 Quick Flash
Night Operation, Sync in Progress
Slow Flashing
Night Operation, Synchronized
Red Status LED
Condition
Steady
Flat Battery cutoff is in effect (Below 10.0V)
Slow
High Voltage (Above 13.5V)
Off
Optimal Voltage (12.5V to 13.5V)
1 Quick
Ok Voltage (12.0V to 12.5V)
2 Quick
Low Voltage (11.5V to 12.0V)
3 Quick
Poor Voltage (10.0V to 11.5V)
4 Quick
Flat Voltage (Below 10.0V)
Trouble Shooting