8
Optional External ON/OFF Switch
The AV-C310-ILA and AV-C410-ILAB can be fitted with an external ON/OFF switch below the solar
panel at the base of the unit. The ON/OFF switch may be useful if the unit is only required for short
periods and is often being moved or needs to be stored often, and disconnecting the battery is not
viable.
Optional External Battery Charging Port
The AV-C310-ILA and AV-C410-ILAB can be fitted with an external battery charging port MIL-STD 2 Pin
connector. (ITT Cannon Part Number = MS3111E82P)
It is found below the solar panel at the base of the unit.
If the light is being stored for more than 1 month then the battery should be regularly recharged.
Please see ‘Long Term Battery Storage’ in the Maintenance & Servicing section of this manual.
You may purchase a suitable battery charger from Avlite
Or/
Use a connector that mates with the 2Pin connector on the unit.
Pin 1(A) = Battery Positive (+)
Pin 2 (B) = Battery Negative (-)
Optional IR Remote Control
The IR remote is used to communicate with Avlite lighting products that have an IR sensor fitted.
The remote control is used to control functions.
Optional GSM Cell-Phone Monitoring (AV-C410-ILAB Model only)
GSM Cell-Phone Monitoring enables operators to remotely monitor the status of their installations. The
system can also be configured to send out alarm SMS text messages to designated cellular telephone
numbers. Users can also have alarms and reports sent to designated email
addresses.
AV-C310-ILA& AV-C410 Optional Configurations