OVATION PH 8.3
7
Getti ng star ted
The update takes about one minute. After successful comple
-
tion you will be asked to switch off the mains voltage (mains
switch 18) and remove the EEPROM Dongle. The device can
now be switched on again and is ready for operation.
ℹ
CAUTION
Do not switch off the PH8.3 during the update process. This
may lead to unstable operating conditions.
If the update process was interrupted, due to a power failure
for example, please proceed as follows: Leave the EEPROM
dongle inser ted. Switch off the mains voltage with the mains
switch (18) on the rear panel for about 10 seconds and then
switch it on again. The software is now installed a second
time. During this process (about one minute) the display (6)
remains dark and the standby LED (5) flashes. When the pro
-
cess is complete, you will be asked to switch off the mains
voltage (mains switch 18) and remove the EEPROM Dongle.
The unit can then be switched on again and is ready for opera
-
tion.
1.6 Installation and cooling
The unit may become hot depending on demanded output
power or environmental temperature. Therefore, it is import
-
ant, that the cooling air can flow unhindered into the air inlet
in the bottom and flow out through the holes in the rear panel.
The cooling openings in the base and rear ensure sufficient
heat dissipation when the unit is freely positioned. The PH 8.3
may be easily installed in a rack as long as the shelf above
the unit is at least 5 cm away from the cover of the device. If