background image

6

www.avonic.eu

The controller has 3 wires: 
• 

Power with female JEITA connector

• 

RS232 with 3 pin Terminal Strip

• 

RS485 with 2 pin Terminal Strip

Maximum distance for RS232 is about 15 meters. Maximum distance for RS485 is about 1200 meters. 

Connection Diagram

RS485 Cable

RS232 Cable

Power (DC12V)

Power Supply

Display

PTZ Camera

Display

PTZ Camera

When connecting multiple cameras through RS-232, use daisy chaining network architecture. Max cable 
length for RS-232 is 10-15m.

VISCA network connection diagram

Controller

Controller

Camera

In      Out

RS-232

RS-232

RS-232

In      Out

In      Out

Camera

Camera

Summary of Contents for CM-CON100

Page 1: ...User Manual Version 1 0 www avonic eu PTZ Camera Controller CM CON100...

Page 2: ...es 4 Installation 5 Connections 5 Connection Diagram 6 VISCA network connection diagram 6 RS485 network connection diagram 7 Addressing Multiple Cameras 7 Operation Instructions 8 Menu 8 What to do if...

Page 3: ...cable Use a soft damp cloth to clean the device do not use strong or abrasive detergent to clean that will damage the device If you wish to dispose this product please contact Avonic to obtain info ab...

Page 4: ...he OSD of the camera through the controller Direct control Pan Tilt Zoom and Focus The Avonic CM CON100 is a compact PTZ camera controller With this controller it is possible to control up to 255 came...

Page 5: ...amera 12 ENT Confirm It is used to confirm menu setting 13 OPEN IRIS Open This key is used to activate IRIS open of the camera It is also a confirm key in a menu 14 Joystick This joystick is used to P...

Page 6: ...um distance for RS485 is about 1200 meters Connection Diagram RS485 Cable RS232 Cable Power DC12V Power Supply Display PTZ Camera Display PTZ Camera When connecting multiple cameras through RS 232 use...

Page 7: ...o the camera or controller is 5m In case more cameras are connected to the controller each camera needs to be addressed the right way to a camera number of the controller The following settings need t...

Page 8: ...8 www avonic eu After powered on USER PIN will show on the controller s screen The initial pin is 111111 Menu OPERATION INSTRUCTIONS...

Page 9: ...9 www avonic eu...

Page 10: ...avonic eu By default the admin pin is set to 1 1 1 1 1 1 If this pin has been changed and is lost use the following mastercode to regain access to the CON 100 7 7 8 8 9 6 What to do if the admin pin i...

Page 11: ...se use a soft dry cloth to clean the controller If the device is very dirty clean it with diluted neuter detergent Do not use any type of solvents which may damage the surface Turn the controller off...

Reviews: