RS485 network connection diagram
The setup for RS485 is a parallel network. To connect multiple cameras by RS485, the
cameras need to get attached to a 2-wire twisted pair bus that is terminated at both ends
with a 120
Ω
impedance resistor. The maximum length of the bus is 1200m. The maximum
distance from the bus to the camera or controller is 5 meters. The cameras are connected
with the 2-pin Phoenix connector. In the OSD menu under Communication Setup, Net mode is
set to Paral.