background image

 
 
 

 

User Manual 

 

Luminaire Installation: 
 

1.  Undo the clips on each side and hinge open the controller.  

 

2.  Fix the base. The base can be fixed via the following methods; once chosen, prepare 

the ceiling/mounting points ensuring the fixing surface/mechanism is enough to 
support the luminaire weight and its application:  
 

 

Surface fixing

: Mount the two stainless steel surface mount fixing clips provided to 

the ceiling at the specified fixing centres. Offer the base up to the clips and push to 
snap fit.  

 

Chain or Wire suspension

: Mount the two stainless steel surface mount fixing clips 

to the base. Then add a V hook (provided in the pack) to each of the surface mount 
clips. This will then provide connection points for chain or wire suspension at the 
specified fixing centres. 

 

Conduit Suspension

: The base comes with specific 20mm diameter drill out points. 

These points are reinforced for conduit suspension purposes. Care must be taken to 
drill a clean hole and not to remove any of the reinforced wall around the hole.  

 

3.  Route the mains supply cable into the base. This can be via the pre-drilled hole with 

compression gland at one end, or via drilling a hole at one of the allocated positions. 
It is the installer

’s responsibility to ensure the IP65 rating is maintained.  

 

4.  Refit the gear tray on to the retaining straps via the snap hooks.  

 

5.  Route the mains supply cable to the terminal block and terminate, ensuring correct 

termination is observed.  
 

6.  Fully locate the gear tray into the base by aligning the slots with the clips in the base 

and securing.  

 

7.   Fit the controller by hinging back into position & securing using the snap-fit clips. 

 

8. 

If vandal resistance is required, fit the small screws provided into each clip.

 

 

9. 

 

Reconnect power supply & check for correct operation. 

 

 
 
 
 
 
 
 

 

Errors and omissions excepted. 

 

Copyright© 2019. AVSL Group Ltd. 