(7) TROUBLE SHOOTING
Fault
Cause
Solution
Light on, but motor does not
work
The flue blocked
Clear the blockage
The capacitor damaged
Replace capacitor
The motor jammed bearing
damaged
Replace motor
Light does not work, motor
does not work
Beside the above mentioned, check the following:
Light damaged
Replace lights
Power cord looses
Connect the wires as per
the electric diagram
Liquid dripping
One way valve and the air
ventilation entrance are not
tightly sealed
Reseal
Leakage from the connection
of U-shaped section and
cover
Take U-shaped section
down and seal
Shake of the body
One way valve damaged and
causes shaking
Replace the one way
valves
The motor is not tightly
hanged
Lock the motor tightly
The body is not tightly
hanged
Fixed the body tightly
Insufficient suction
The distance between the
body and the ducting outlet is
too long
Readjust the distance
Too much ventilation from
open doors or windows
Choose a new place and
reinstall hood
The machine inclines
The fixing screw not tight
enough
Tighten the hanging
screw to return back to
horizontal position
The hanging screw not tight
enough
Tighten the hanging
screw to return back to
horizontal position
Summary of Contents for CHO83-900