| VoIP Settings
Dial Plan
69
When a user dials a series of digits, the dial-plan rule is tested for a
possible match. If a match is made, the dialed sequence is transmitted. If
no match is made, the dialed number is blocked and the user will hear an
error tone.
A dial-plan string cannot include spaces between elements. Dialed
sequences that are longer than specified in a dial-plan rule are truncated
after the number of specified digits. For example, if the dial-plan rule is
011x
and
0115678
is dialed, only the digit sequence
0115
is
transmitted.
[ ]
[125-8]
Limits a dialed digit to specified values or a range of values. The
example specifies that only digits 1, 2, 5, 6, 7, and 8 are
permitted.
t
xx.t
The timeout indicator that can placed after dialed digits or at the
end of the dial-plan string.
Table 5: Dial Plan Elements
Element
Example
Description