Sanitizing Instructions
1.
Make a mild sanitizing solution by adding one-half ounce of
5.25%
(laundry strength) chlorine
bleach to 1 gallon of water.
2. Turn off RO System, drain storage tank, and remove membrane element and pre-filters.
3. Membrane element must remain wet. Put membrane element in a plastic bag.
4. Fill empty pre-filter housing with sanitizing solution and turn on raw water. After holding tank
is full, let system stand idle for approximately 30 minutes.
5. Turn off water.
6. Drain holding tank via the R.0. faucet.
7. Reinstall new pre-filters and membrane element.
8. Replace post filter.
9. Disconnect line to faucet (and ice maker] and
put
approximately 10 drops of sanitizing
solution
in
these lines and reconnect.
10.
Follow start-up procedure to restart
unit.
(Refer to previous page)