background image

 

 
 
 

 

3.  IMPORTANT SAFETY NOTICE                                                          

 

Read all Instructions before Installing and operating this appliance 

 

Installation Cautions 

 

The installation in this manual is intended for qualified installers, service technicians or persons with 

similar qualified background. Installation and electrical wiring must be done by qualified professionals 

and in accordance with all applicable codes and standards, including fire-rated construction. 

 

 

DO NOT attempt to install this appliance yourself. Injury could result from installing the unit due to lack 

of appropriate electrical and technical background. 

 

 

Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any 
parts for installing, cleaning or servicing. 

 

 

Before installation, turn on the range hood to test for any damage / defect due to shipping. 

 

 

Due to the size and weight of this range hood, two people installation is required. 

 

To reduce the risk of fire, electric shock, or injury to persons: 

 

For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and vapors. 

 

The combustion air flow needed for safe operation of fuel-burning equipment may be affected by this 

unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as 

those  published by the National Fire Protection Association (NFPA), and the American Society of 

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 

 

 

Before servicing or cleaning unit, unplug the power cord or switch power OFF at service panel and lock 

service panel to pre-vent power from being switched ON accidentally. 

 

 

Clean grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly, make sure 

to vent air outdoors. DO NOT vent exhaust into spaces between walls, crawl spaces, ceiling, attics or 

garages. 

  

 

Use only metal ductwork and this unit MUST be grounded. 

 

 

Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent back 

drafting. 

 

 

When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden 

utilities. 

 

 

All electrical wiring must be properly installed, insulated and grounded. 

 

 

Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire. 

 

 

Check all joints on duct work to insure proper connection and all joints should be properly taped. 

 

Use this unit only in the manner intended by the manufacturer. If you have questions, contact the vendor. 

 

To reduce the risk of a stove top grease fire: 

 

Keep all fan, baffle, spaces, filter, grease tunnel, oil container and grease-laden surfaces clean. Grease 

should not be allowed to accumulate on fan, baffle, spaces, filter, and grease tunnel and oil container. 

 

 

Always turn range hood ON when cooking at high heat or when cooking flaming foods. 

 

 

Use high settings on cooking range only when necessary. 

 

Never leave surface units (countertop/stove) unattended at high settings. Boil overs cause smoking and 
greasy spillover that may ignite. Heat oils slowly on low or medium settings. 

 

Clean ventilating fan frequently. 

 

Summary of Contents for RH-SP08

Page 1: ...nit to the Blower unit s 5 wires corresponding to the colors inside the top connection box 5 Plug in 120V AC power source Press the power button and the speed buttons to turn on 6 Check if any unusual metal touching noise check the speed variation and press the Light button to check the lights 7 Verify all functions per Section 9 RANGE HOOD OPERATIONS 8 Refer to Section 10 TROUBLESHOOTING if any m...

Page 2: ...by qualified person s in accordance with all applicable codes and standards including fire rated construction C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Verify and ensure the rated voltage and frequency please refer to the rating label of the range hood is in compliance with the mains supply CONTENTS 1 KNOW BEFORE INSTALLATION 2 2 I...

Page 3: ...The 8 round ducts are NOT included Recommend to purchase 8 semi rigid aluminum ducts Refer to Section 5 VENTING METHODS for detail Check the existing exhaust duct size If not 8 round metal duct try to get the converter reducer adapter elbow as shown in the pictures The air damper is NOT included Also prepare the cutting tools jig saw or reciprocating saw screw drivers or power drill level measurin...

Page 4: ...wer Unit Top Connection Box 2 INCLUDED PARTS ACCESSORIES Note The Blower unit must be kept inside the home attic or crawl space etc Never try to install the Blower outside of the home The supplied are subjected to change without notice due to product development ...

Page 5: ...ities Before servicing or cleaning unit unplug the power cord or switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outdoors DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Use only meta...

Page 6: ...he lights or any type of appliance Open all doors and windows to disperse the gas If you still smell gas call the gas company and fire department or 911 immediately Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages All safety messages will tell you what the potential ...

Page 7: ...ost efficient quiet operation A distance of 24 to 27 is recommended between stove top and the bottom of range hood The vent duct isn t included It is recommended that the range hood be vented vertically through the roof through 8 or bigger round metal aluminum vent work such as 8 in x 8 ft semi rigid aluminum flexible duct The size of the vent should be uniform Use no more than three 90 elbows Mak...

Page 8: ...ht Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will reduce its performance and efficiency If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range Minimum Duct Size Round 8 minimum Recommend to purchase 8 semi rigid aluminum ducts Calculating Vent S...

Page 9: ...gid type metal aluminum ducts if available to maximize airflow Decide the location of the venting pipe from the hood to the outside Astraight short vent run will allow the hood to perform more efficiently Try to avoid as many transitions elbows and long run as possible This may reduce the performance of the hood IMPORTANT NEVER exhaust air or terminate duct work into spaces between walls crawl spa...

Page 10: ...ted directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable ETL listed strain relief must be provided at each end of the power supply cable Specifications Specifications Body Design Seamless Stainless Steel Satin Finish Power Rating 120V 60Hz USA Canada standard General Input Power 236W 230W 2x3W Motor Input Power 230W Ampere 2 5 A Lev...

Page 11: ...ll the hood unplug the power on an electric range SHUT OFF THE GAS VALVE BEFORE MOVING A GAS RANGE 8 INSTALLATION INSTRUCTIONS 1 Installation planning Measure the distance between stove top and the bottom of range hood A distance of 24 to 27 is recommended Minimum 24 is required for safety concern Decide the venting method and the location of the venting pipe from the hood to the outside Purchase ...

Page 12: ...amps and foil tape or duct tape to make all joints secure and air tight 8 Connect the Speed Control Cord from the hood to the top connection box of the Blower Unit make sure the wires are securely connected using the provided electrical nuts according to the colors Note the Black wire is Neutral in this Speed Control Cord 9 Connect the power cord to a designated grounded standard 110V outlet Or cu...

Page 13: ...peed Control button can be activated Blower Speed Selection With the range hood is OFF press the Power Control On Off button once The LED on the Power Control button will be illuminated While the Power Control LED is illuminated press one of the four speed control button Quiet Low Medium and High to activate the desired speed the LED on the speed control button will turn on To change the fan speed...

Page 14: ...ibrates when the blower is on The range hood might not have been secured properly on to the cabinet or wall The blower or fan seems weak Check that the duct sized used is at least 8 Range hood WILL NOT function efficiently with insufficient duct size Check if duct is clogged or if air damper unit half circular flapper is not installed correctly or opening properly A tight mesh on a side wall cap u...

Page 15: ... onto or into the control panel Follow directions of the stainless steel cleaner CAUTION DO NOT leave on too long as this may cause damage to hood finish Use soft towel to wipe off the cleaning solution gently rub off any stubborn spots Use dry soft towel to dry the hood After cleaning you may use nonabrasive stainless steel polish to polish and buff out the stainless luster and grain Always scrub...

Page 16: ...anty is extended to the original purchaser for products purchased for ordinary home use in the continental USA This Warranty Will Be Voided When Product damaged through negligence improper installation accident abuse misuse natural disaster insufficient or excessive electrical supply abnormal mechanical or environmental conditions or any unauthorized disassembly repair modification or failure to f...

Page 17: ...rranty service you may contact us its dealer or distributor from which you purchased the product Please confirm the terms of your dealer s or distributor s policies prior to contacting Typically you must include product identification information including model number and lot number with a detailed description of the problem you are experiencing You must also include proof of the date of original...

Reviews: