The AWS Wind Turbine has been designed with your safety in mind. However,
there are inherent dangers involved with any electrical and/or mechanical
equipment. 

Safety must be your primary concern as you plan the location,

installation and operation of the turbine. At all times be aware of electrical,
mechanical and rotor blade hazards.

1.1 MECHANICAL HAZARD

Rotating blades present the most serious hazard. The rotor blades are made of very 
strong thermoplastic. At the tip, the blades may be moving at velocities over 275 miles 
per hour (440 km/hr). At this speed, the tip of a blade is nearly invisible and can cause 
serious injury. Under no circumstances should you install the turbine where a person 
could come in contact with moving rotor blades.  DO NOT INSTALL THE TURBINE 
WHERE ANYONE CAN APPROACH THE PATH OF THE BLADES.

1.2 ELECTRICAL HAZARDS

*Observe all manufacturers' safety procedures when working around batteries and

 

other electrical equipment.

The 

AWS

 Wind Turbine is equipped with sophisticated electronics designed to provide 

protection from high surge electrical dangers. The internal electronics of the 

AWS

 Wind 

Turbine prevents open circuit voltages from rising above 20 volts for 12-volt systems. Please 
note that the inherent personal dangers from electrical

 

current still exist, therefore caution 

should always be used when connecting this
and other electrical devices.

Heat in wiring systems is often a result of too much current flowing through an 
undersized wire or through a bad connection.

Batteries can deliver a dangerous amount of current. If a short occurs in the wiring 
from the batteries, a fire can result. In order to avoid this threat, a properly sized fuse 
or circuit breaker is required in the lines connecting to the battery.

1.3 INSTALLATION PRECAUTIONS:

Installation procedures should be performed at ground level. 
Make sure that all batteries are disconnected throughout the installation process.
Never install the AWS Wind Turbine upside down. 
Choose a day when the wind is calm.

1. PRECAUTIONS

Connect the 2 wires coming from the Wind Turbine to the control switch panel. 
Then, connect control panel output wires to the battery bank.
From Wind turbine and swtich panel has two wires(Black = Negative (-)
 Red = positive (+))  ensuring they do not made a mistake.

1.4 OPERATION PRECAUTIONS

Summary of Contents for AWS400W

Page 1: ...Please read and understand this manual completely before operating the machine Serial number AUSTRALIAN WIND AND SOLAR www australianwindandsolar com AWS400W Wind Turbine Ver 2 3 Revised 6 5 2020...

Page 2: ...2...

Page 3: ...R WIRING 6 3 INSTALLATION OPERATION 6 4 ATTACHING TO POLE 6 5 STEP BY STEP INSTRUCTION 7 WARRANTY POLICY 7 1 ELEVATION 8 WARRANTY 4 4 4 4 5 6 6 7 8 9 10 11 11 12 15 15 16 AWS Marine grade 400 Watt Win...

Page 4: ...high surge electrical dangers The internal electronics of the AWS Wind Turbine prevents open circuit voltages from rising above 20 volts for 12 volt systems Please note that the inherent personal dan...

Page 5: ...the turbine rotor will require approximately 60 100 hours of operation in normal wind speeds approximately 18 20 mph 8 9 m s before they are running at peak efficiency During this break in period the...

Page 6: ...t shrink not included Wire strippers not included Wire crimpers not included NOTE Do not connect to the battery Precheck Spin rotor shaft slowly with your fingers while at the same time connecting and...

Page 7: ...bulence Smooth laminar airflow 2H 20H Turbulent airflow 2H H Turbulent airflow created by obstructions Ad P Gipe 93 Therefore as a general rule the Wind Generator should be mounted twice as high as an...

Page 8: ...cost and effort of the installation This Wind Generator is designed to use steel pipe 1 875 inch 48mm outside diameter equivalent to 1 inch SCH 40 pipe which can be used in some tower applications If...

Page 9: ...perature exceeded 90C or temperature sensor damage Rotor rotating at 0 1000rpm Normal mode Flashing green Charging wind speed to 10m s to 14m s Rotor rotating at 1000rpm to 1300rpm System returns to n...

Page 10: ...ily damaged internal controller in wind condition the warranty will not covered The power meter box main function is display and break the wind turbine the MPPT controller in the wind turbine body Pow...

Page 11: ...CAREFULLY NOTE DO NOT install the blade assembly until the body is mounted on the tower CAUTION ALL BATTERIES MUST DISCONNECTED THROUGHOUT THE INSTALLATION PROCESS CAUTION DO NOT INSTALL THE WIND GEN...

Page 12: ...generator by the pipe 3 Connect the Wind Generator to the wires and insulate the connections using either heat shrink tubing or a quality electrical tape 4 Once the yaw shaft is on the tower firmly t...

Page 13: ...blades assembly onto the rotor shaft and place the nut on the shaft DO NOT press the rotor shaft into the body Caution over torque will damage the blades and wind generator M16 NUT 8 Insert the 8mm he...

Page 14: ...m should be connected to a ground This is usually done by connecting a wire from the negative battery terminal to a nearby ground rod Wires with the same ratings as the positive and negative wires mus...

Page 15: ...8 000 9 000ft 9 000 10 000ft 150 300m 300 600m 600 900m 900 1 200m 1 200 1 500m 1 500 1 800m 1 800 2 100m 2 100 2 400m 2 400 2 700m 2 700 3 000m 97 94 91 88 85 82 79 76 73 70 7 1 ELEVATION An importa...

Page 16: ...r com Warranty Registration Card Warranty Service Card Model Number Installation Location Model Number Application Procedure Problem Description Total Work Period Other Requirements Send at least thre...

Reviews:

Related manuals for AWS400W