6.1. Single wind generator
See Diagram below for further wiring information
Wind T urbine G enerator
The controller Indicator Lamp
9
red
Black
Mode
Lamp
Status
Cause
Normal mode
Stop mode
Solid Green
Flashing red
Charging wind speed
3
.
13m
/
s
to
10
m/s
Rotor ro
ta
ting at low
spin or stop
Rotor ro
ta
ting at low
spin or stop
9
Flashing red
and
green
light
alternatively
The alternator
temperature
exceeded 90C or
temperature sensor
damage
Rotor
rotating at
0-1000rpm
Normal mode
Flashing green
Charging wind
speed to
10
m/s
to
14m
/
s
Rotor
rotating at
1000rpm to 1300rpm
System returns to
normal mode if the
battery voltage
drops below 13.1V,
24V system 26.2V
Normal Mode
Battery fully charged
(voltage exceeds 14.2V)
or 24V system 28.4V
Normally
Normally
Operation
System returns to
normal mode if the
control
temperature drops
below 60C
Control box
Stop mode
Solid
red
Rotor ro
ta
ting at low
spin or stop
The output is reach peak
power.
It will stop 8mins
and restart again