AWS Storage Gateway User Guide
Network and Firewall Requirements
In addition to the common ports, volume and tape gateways require the following port.
Protocol
Port
Direction
Source
Destination
How Used
TCP
3260 (iSCSI)
Inbound
iSCSI Initiators
Storage
Gateway
By local
systems to
connect to
iSCSI targets
exposed by the
gateway.
For detailed information about port requirements, see
in the
Additional
AWS Storage Gateway Resources
section.
Networking and Firewall Requirements for the AWS Storage
Gateway Hardware Appliance
Each AWS Storage Gateway Hardware Appliance requires the following network services:
•
Internet access
– an always-on network connection to the internet through any network interface on
the server.
•
DNS services
– DNS services for communication between the hardware appliance and DNS server.
•
Time synchronization
– an automatically configured Amazon NTP time service must be reachable.
•
IP address
– A DHCP or static IPv4 address assigned. You cannot assign an IPv6 address.
There are five physical network ports at the rear of the Dell PowerEdge R640 server. From left to right
(facing the back of the server) these ports are as follows:
1. iDRAC
2.
em1
3.
em2
4.
em3
5.
em4
API Version 2013-06-30
17