background image

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.

v1710v31

16

Overview installation codes FP070 / FP035

Description

Code

FP070

FP035

Restore factory settings

2412

Erase Memory

2499

Update Firmware

2810

User Interface Update

2811

Update Tunes

2812

Format SD-card

2813

Send adjusted namelist to other monitors

2910

Configure monitor as Master

8000

Configure monitor as Slave 1-3

8001-8003

Configure Guard monitor (8004) or deactivated (8005)

8004-8005

Video active on slaves when calling (8006) or deactivated (8007)

8006-8007

Date format: MM//DD/YYYY (8008) of DD/MM/YYYY (8009)

8008-8009

Lock output as Normally Open (8010) or Normally Closed (8011)

8010-8011

Time format: 12-Hr (8012) or 24-Hr (8013)

8012-8013

Unlocking menu active (8014) or deactivated (8015)

8014-8015

Monitor not available when BUS is active (8016) or available (8017)

8016-8017

Videoformat: Automatic (8018), PAL (8019) or NTSC (8020)

8018-8020

Unlocking time between 1-9 s

8021-8029

Indicating light will light up in red, green, blue, yellow or purple when calling

8040-8044

Indicating light will blink red, green, blue, yellow, purple or white when 

calling

8045-8050

Indicating light will blink red, green, blue, yellow, purple or white in standby

8051-8056

Indicating light is deactived

8057

Automatic recording is active (8300) or deactivated (8301)

8300-8301

Manual recording possible (8302) or deactivated (8303)

8302-8303

Unlocking time between 1-99 seconds

8401-8499

Warning during unlocking (9006: OFF, 9007: ON)

9006-9007

Tune Type (9008: Auto, 9009: Default, 9010: Reserved)

9008-9010

Start namelist from 0 (9011) or 1 (9012)

9011-9012

Touchscreen tap sounds active (9013) or deactivated (9014)

9013-9014

Intercomcall possible (9015) or deactivated (9016)

9015-9016

Configure sensibility of the touch screen

9017-9019

Hearing Aid function (T-coil) (Not available)

9020-9021

Zoomfactor when using fisheye-objective

9030-9039

Frequently Asked Questions

Visit our online shop: https://shop.seculux.be

Productpages will show manuals, faq, brochures and more

Summary of Contents for entrya Facila

Page 1: ...Installation Guide 2017 Facila...

Page 2: ...e 8 Multiple monitors with multiple distributors 8 Camera module 9 Multiple door stations and a lock module with a distributor 9 Cabling requirements APPARTMENT system 10 Topology Star network 10 Topo...

Page 3: ...ions between devices In a FACILA BUS the data audio power and vide osignals have been integrated on two wires When a connected device on a BUS wants to commu nicate with another device on the same BUS...

Page 4: ...impedance switch is switched on at the monitor and distributor which are last on the BUS line Double twisted cable Connect half colored wires and full colored wired to twist twisted wires Use the brow...

Page 5: ...elding 2x 0 75mm 60m 40m Twisted pair without shielding 2x 1mm 80m 60m A Maximum cable length between PSU and door station B Maximum cable lenght between PSU and the last monitor A B Topology Cascade...

Page 6: ...etween PSU and the last distributor C Maximum cable length between distributor and the last monitor B C In a star network all devices communicate through distributors The advantage of such a star topo...

Page 7: ...no other device may have this address Example schematics Basic schematic Basic schematic with lock module Multiple door stations with a distributor Multiple monitors with a distributor Multiple monit...

Page 8: ...uide are protected by copyright and intellectual property of ENTRYA BVBA v1710v31 8 Multiple monitors with distributor in combination with a lock module Multiple monitors with multiple distributors PS...

Page 9: ...exts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA 9 Camera module PSU Multiple door stations and a lock module with a distributor PSU Distributor Lock m...

Page 10: ...Twisted pair without shielding 2x 1mm 70m 30m 20m Twisted pair without shielding 2x 1 5mm 70m 50m 30m A Maximum length between PSU and door station B Maximum length between PSU and the last distribut...

Page 11: ...werk is dan ook geschikt voor nieuwbouwprojecten Een serienetwerk vereist minder kabels dan een sternetwerk maar bij problemen wordt het volledige netwerk verstoord A Maximum length between PSU and do...

Page 12: ...has address 15 no other device may have this address Example schematics Basic schematic Basic schematic with lock module Multiple door stations with distributor Multiple monitors with distributor Mul...

Page 13: ...nd intellectual property of ENTRYA BVBA 13 Multiple monitors with a lock module and a distributor Multiple monitors with multiple distributors PSU PSU Distributor Lock module Important Switch terminat...

Page 14: ...and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA v1710v31 14 Camera module PSU Multiple door stations with lock module and distributors PSU Distributor Loc...

Page 15: ...s installed at the end of the BUS line to guarantee that the required tension does not go below 23V DC Before installing a supplementary PSU it is important that one measures the tension on the BUS wh...

Page 16: ...AL 8019 or NTSC 8020 8018 8020 Unlocking time between 1 9 s 8021 8029 Indicating light will light up in red green blue yellow or purple when calling 8040 8044 Indicating light will blink red green blu...