background image

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.

3

Preface

The FACILA-system is designed with a focus on usability. A two-wiresystem that is not sensible to 

polarity, guarantees a quick and easy installation.

The multi-use of our monitors ensures an answer for every installation. Call forwarding, videosur-

veillance, mobile forwarding, standard and panic-lock activations and controlling gate operators, 

FACILA has quick solutions for every case.

This guide is a supplement to the manuals of the monitors, doorstations and accessories 

and does not replace the actual manuals!

Team Entrya!

Legend

Doorstation

Monitor

Accessory

PSU

Notions

BUS system

A ‘BUS’ is a signalline which has multiple devices connnected parallel. The purpose is to diminish 

the number of connections between devices. In a FACILA-BUS the data-, audio-, power- and vide-

osignals have been integrated on two wires. When a connected device on a BUS wants to commu-

nicate with another device on the same BUS, it can only do so when the signalline is not occupied. 

The device will put the address of the device it searches on the BUS so that it is clear which device 

is requested. Giving each device a correct address is therefore very important.

Model Master/Slave

In a Master/Slave setup one device controls all other. The Master receives the call from the 

doorstations and redistributes the signals to possible Slave-monitors with the same address. An 

installation has at least one Master-monitor.

Schematic overview of a Master/Slave setup

Master

Address 0

Address 1

Master

Slave 1

Slave 1

Slave 2

Slave 2

00.00

01.00

00.10

01.10

00.20

01.20

The Master/Slave setup is default because it groupes several monitors to one address. 

This makes it possible to have up to 4 monitors for each installation (1x Master and 3x Slaves).

Summary of Contents for entrya Facila

Page 1: ...Installation Guide 2017 Facila...

Page 2: ...e 8 Multiple monitors with multiple distributors 8 Camera module 9 Multiple door stations and a lock module with a distributor 9 Cabling requirements APPARTMENT system 10 Topology Star network 10 Topo...

Page 3: ...ions between devices In a FACILA BUS the data audio power and vide osignals have been integrated on two wires When a connected device on a BUS wants to commu nicate with another device on the same BUS...

Page 4: ...impedance switch is switched on at the monitor and distributor which are last on the BUS line Double twisted cable Connect half colored wires and full colored wired to twist twisted wires Use the brow...

Page 5: ...elding 2x 0 75mm 60m 40m Twisted pair without shielding 2x 1mm 80m 60m A Maximum cable length between PSU and door station B Maximum cable lenght between PSU and the last monitor A B Topology Cascade...

Page 6: ...etween PSU and the last distributor C Maximum cable length between distributor and the last monitor B C In a star network all devices communicate through distributors The advantage of such a star topo...

Page 7: ...no other device may have this address Example schematics Basic schematic Basic schematic with lock module Multiple door stations with a distributor Multiple monitors with a distributor Multiple monit...

Page 8: ...uide are protected by copyright and intellectual property of ENTRYA BVBA v1710v31 8 Multiple monitors with distributor in combination with a lock module Multiple monitors with multiple distributors PS...

Page 9: ...exts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA 9 Camera module PSU Multiple door stations and a lock module with a distributor PSU Distributor Lock m...

Page 10: ...Twisted pair without shielding 2x 1mm 70m 30m 20m Twisted pair without shielding 2x 1 5mm 70m 50m 30m A Maximum length between PSU and door station B Maximum length between PSU and the last distribut...

Page 11: ...werk is dan ook geschikt voor nieuwbouwprojecten Een serienetwerk vereist minder kabels dan een sternetwerk maar bij problemen wordt het volledige netwerk verstoord A Maximum length between PSU and do...

Page 12: ...has address 15 no other device may have this address Example schematics Basic schematic Basic schematic with lock module Multiple door stations with distributor Multiple monitors with distributor Mul...

Page 13: ...nd intellectual property of ENTRYA BVBA 13 Multiple monitors with a lock module and a distributor Multiple monitors with multiple distributors PSU PSU Distributor Lock module Important Switch terminat...

Page 14: ...and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA v1710v31 14 Camera module PSU Multiple door stations with lock module and distributors PSU Distributor Loc...

Page 15: ...s installed at the end of the BUS line to guarantee that the required tension does not go below 23V DC Before installing a supplementary PSU it is important that one measures the tension on the BUS wh...

Page 16: ...AL 8019 or NTSC 8020 8018 8020 Unlocking time between 1 9 s 8021 8029 Indicating light will light up in red green blue yellow or purple when calling 8040 8044 Indicating light will blink red green blu...

Reviews: