background image

21

Base tub, impeller and level regulating valve

Hepa filter (PH7 Plus only)

2

ca. 2 kg

1

4

3

Accumulation of lime in the base tub, on the impeller or
in the level regulating valve promotes the development
of microorganisms which may lead to unpleasant odour.
If there is accumulation of lime, use a commercially avail-
able deliming agent (e.g. acetic cleaning agent or 8-
percent formic acid), then rinse thoroughly with fresh
water.
If there is no formation of lime, clean the parts with luke-
warm soapy water, then thoroughly rinse with fresh
water.

Water tank

Rinse with hot water. Clean the water tank with acetic
cleaning agent as required, then thoroughly rinse with
fresh water

Activated charcoal vaporizer mat

Carefully rinse the vaporizer mat with luke-
warm water (without additives), as re-
quired. The vaporizer mat must be re-
placed after it has been in use for 3 months
at the latest
. The vaporizer mat is non-
polluting and may be thrown in the trash.

Filter slightly soiled/filter in use for less
than 6 months
:
Vacuum the filter on both sides (use the
lowest power setting of the vacuum clean-
er).

Filter replacement indicator is activated
(all LEDs are blinking): replace filter.

Triplex filter (PH7 only)

Filter replacement indicator is activated
(all LEDs are blinking): replace filter.

The Hepa filter cannot be cleaned.

Reassembling the unit

Caution! Before reassembling the Axair PH7 check
all components for possible damage. Do not reuse
damaged parts but replace them before reassem-
bling the unit.
For the replacement of defective components
(e.g. mains cable, indicator lamp, etc.) please
contact your Axair supplier
.

1. Push the impeller into the snap lock of the fan until it

properly engages.

2. Important! After the impeller has properly engaged, turn

it back and forth a couple of times. Then have the
impeller rotate at high speed and check for eccentricity.
Repeat above procedure as required.

3. Insert the air intake screen into the notches of the base

tub, then lock the screen by turning it clockwise to the
stop.

4. Locate the tank base in the base tub, then press the base

down until it properly engages in the snap lock of the
base tub.

Summary of Contents for PH7

Page 1: ...Axair PH7 Operating Instructions Air purifier humidifier 1118887 D E F 0308 ...

Page 2: ...duct overview 17 3 1 Design 17 3 2 Functional description 17 3 3 Unpacking checking the delivery and removing the transport lock 17 4 Notes on correct location 18 5 Operation 18 6 Maintenance and cleaning 20 6 1 Maintenance intervals 20 6 2 Maintenance 20 6 3 Disposal 22 7 What if 23 8 Technical data 24 9 Spare parts list 25 Contents ...

Page 3: ...st not operate the unit unless under supervision Except for the steps mentioned in this manual the user must not carry out further operations with the Axair PH7 All repairs e g replacement of the mains cable or replacement of the control unit etc must be carried out by your Axair supplier only Danger of electrical shocks The Axair PH7 operates at mains voltage observe all local safety regulations ...

Page 4: ...tivated charcoal vaporizer mat Finally the purified and moistened air is exhausted to the room via the slots in the upper part of the housing Note If the Axair PH7 is operated without water it works as air purifier only and no humidification takes place 3 3 Unpacking checking the delivery and removing the transport lock Unpack the Axair PH7 Important The original packaging of the Axair PH7 was des...

Page 5: ...o not locate the PH7 close to cold outer walls and do not expose the unit to direct sunlight or powerful heat sources lamps radiators etc If the Axair PH7 is used in a particular location for an extended period the filter and the activated charcoal vaporizer mat absorbs the odour of the room When moving the unit to another location the Axair PH7 emits the odour of the previous room for a certain t...

Page 6: ...speed key to select the desired fan speed according to the fol lowing table PH7 PH7 Plus Fan speed I II I II III Air recirculation in m3 h 100 145 80 100 130 Vaporizing capacity in dl h 3 0 4 0 2 8 3 5 4 0 at 45 hr and 23 C Notes on operation Check the level of the water tank on a regular basis and fill up as required see section Refilling the water tank Recommendation for optimum purification the...

Page 7: ...the Axair PH7 off remove the mains plug from the wall outlet and wait until the fan comes to a stop 2 Swivel up the carrying handles of the water tank and remove the water tank to the top 3 Lift up the hood Pull out the mains cable from the cable duct in the air intake screen Then carefully lift up the fan housing and put it aside with the impeller on top Caution To prevent damage make sure the im...

Page 8: ... filter in use for less than 6 months Vacuum the filter on both sides use the lowest power setting of the vacuum clean er Filter replacement indicator is activated all LEDs are blinking replace filter Triplex filter PH7 only Filter replacement indicator is activated all LEDs are blinking replace filter The Hepa filter cannot be cleaned Reassembling the unit Caution Before reassembling the Axair PH...

Page 9: ... down to the base tub 6 7 8 9 10 5 6 Fold the activated charcoal vaporizer mat as shown in the figure above then insert the mat into the base tub Finally unfold the activated charcoal vaporizer mat and press it towards the inner ridge of the base tub Important Make sure the activated charcoal vaporizer mat is properly seated at the bottom of the base tub and does not rest on the ridge 9 Fill up th...

Page 10: ...of the fan housing and or filter badly soiled Clean impeller Clean or replace activated charcoal vaporizer mat Fill up water tank Clean fan housing Clean or replace filter Unit is switched on all LEDs are blinking filter replacement indicator Filter and or activated charcoal vaporizer mat soiled Clean or replace Filter and or activat ed charcoal vaporizer mat Important After filter replacement re ...

Page 11: ...r consumption at 230 V W 17 24 12 15 26 Acoustic capacity level dBA 46 53 44 48 52 Sound intensity level dBA 40 47 38 42 46 Impeller polystyrene attached to fan Triplex filter Structure coarse filter activated charcoal filter fine dust filter Filter surface 0 2 m2 Activated charcoal vaporizer mat polyurethane foam with activated charcoal coating Water tank made of transparent SAN with incorporated...

Page 12: ...porizer mat 1118615 10 Hood large 1118664 11 Impeller cpl 1104377 12 Support 1118661 13 Fan 1118665 14 Motor support 1118662 Pos Spare parts Type SAP No 15 Set of rubber bearings 3 pcs 1118670 16 Motor 2 step 230 V 1118666 2 step 100 V 1118667 3 step 230 V 1118668 3 step 100 V 1118669 17 Mains cable normal 1103268 Japanese 1115938 Korean 1105876 18 Control unit 2 step 230 V 1118672 2 step 100 V 11...

Page 13: ...Notes ...

Page 14: ...Air Treatment A WMH Walter Meier Holding Company CH 8808 Pfäffikon Switzerland Talstr 35 37 P O Box Telephone 41 55 416 6111 Fax 41 55 416 62 62 Internet http www axair ch E Mail info axair ch Consulting Sales and Service Reg No 40002 2 ...