22
5. Insert the Triplex filter (or the Hepa filter, respectively)
into the base tub (Important! Make sure the filter does
not get in contact with water, otherwise the filter must
be replaced).
Important! When inserting the Triplex filter make sure
the entire inner perimeter of the filter is located behind
the ridge of the air intake screen.
Important! When inserting the Hepa filter make sure
the entire inner perimeter of the filter is evenly located on
the ridge of the air intake screen.
7. Place the fan housing on the air intake screen and align
both parts. Then, put on the hood.
8. Lead the mains cable via the cable duct of the air intake
screen down to the base tub.
6
7
8
9
10
5
6. Fold the activated charcoal vaporizer mat (as shown in
the figure above), then insert the mat into the base tub.
Finally, unfold the activated charcoal vaporizer mat and
press it towards the inner ridge of the base tub.
Important! Make sure the activated charcoal vaporizer
mat is properly seated at the bottom of the base tub and
does not rest on the ridge.
9. Fill up the water tank (if required) and attach it to the unit.
10. Reset the filter replacement indicator: Connect the
mains plug to the wall outlet. Then, simultaneously
press the On/Off and the fan speed keys and keep
them depressed (approx. 4 seconds) until all LEDs
light up briefly (approx. 2 seconds).
6.3
Disposal
Please observe the local regulations for correct disposal of
the entire unit or particular components . If in doubt, consult
your Axair supplier.