background image

 

OUTPUT MODULES DESCRIPTION (OXYGEN 3 and 3 ST)                

ENG 

                                                                                                                                                                 Pag. 15 

11  OUTPUT MODULES DESCRIPTION (OXYGEN 3 and 3 ST) 

 

11.1 MASTER section 

 

 
OUTPUT 1
: it controls the signal level on the output labelled OUTPUT 1 (balanced). 
 
OUTPUT 2: it controls the signal level on the output labelled OUTPUT 2 (balanced). 
 
BALANCE: it controls the signal balance on the outputs labelled OUTPUT 1-2-3 and 
FIXED. 
 
OUTPUT 3: it controls the signal level on the output output labelled OUTPUT 3 
(unbalanced). 
 
 
 
 

11.2  TALK OVER section 

 
The TALK OVER section allows compression of all signals from CH 2 to 6 and of the 
TELEPHONE channels in favour of CHANNEL1 (Master) output signal. It means that you can, f.i., 
automatically fade the level of music signals (from Stereo module) depending on the level of MIC1 
microphone signal. This section will affect the MASTER outputs. 
 
DEPTH: it controls the ratio of the compression: the lower is the value, the lower will be the 
compressed audio level. The TALK OVER function can be disabled by turning the DEPTH 
potentiometer in position 10
 
THR(ESHOLD): the trimmer inside the hole adjusts the threshold intervention level of the 
compressor (use a small screw-driver in order not to damage the trimmer). 
 
REL(EASE): adjusts the release time of compressor: the higher is the value (turn it 
clockwise), the longer is the time needed to go back to the former audio level. (use a small 
screw-driver not to damage the trimmer). 
 
 

11.3 MONITOR section 

 
The Monitor section allows monitoring of selected buses (Ext In, Master, and PFL) without 
interfering with normal operation of the main (Master) audio bus. For operator assistance, 
the left pair of LED meters always visualize the level of the source selected in this section. 
 
The Monitor section is capable of driving one pairs of headphones plus a Line output with 
separated level controls. 
 
POWER  button: it switches On / Off the console. The LED inside the button glows 
accordingly. 
 
EXT IN control: it adjusts the EXT IN input signal level (for example a tuner signal) 
 
OUT control: It affects the (line level) Monitor output on the rear panel.  
 
HEADPHONE control: it affects the output to any headphones connected to the 1/4” jack 
phones socket 
 

Summary of Contents for Oxygen 3

Page 1: ...anual Rel 1 2 Via Caduti Di Sabbiuno 6 F 40011 Anzola Emilia Bologna Italy Tel 39 051 736555 Fax 39 051 736170 e mail info axeltechnology com web site www axeltechnology com Oxygen 3 3ST Broadcast Mix...

Page 2: ......

Page 3: ...tputs 9 7 2 MONITOR OUT and EXT IN connections OXYGEN 3 and 3 ST 10 7 3 LED METERS 10 8 OXYGEN 3 INPUT MODULE DESCRIPTION 11 8 1 CHANNELS 1 to 6 11 9 OXYGEN 3 ST INPUT MODULE DESCRIPTION 12 9 1 CHANNE...

Page 4: ...wet switch off and remove mains power immediately Refer servicing to qualified technical personnel only Servicing Switch off the equipment and unplug the power cord immediately if it is exposed to mo...

Page 5: ...no additonal items in order to be operated All relevent functions are built in such as Monitor speaker muting and On Air lamp control facility available on series on the Channel 1 module and as an op...

Page 6: ...2 CH 4 and 5 The channels feature two selectable inputs INPUT A PIN RCA LINE input INPUT B PIN RCA LINE input the A input can be set if required as PHONO too 4 3 CH 6 The channel features two selectab...

Page 7: ...Ground Ground Ring Return Tip Signal 5 2 CH 4 5 and 6 The channels feature two selectable stereo inputs INPUT A LINE input electronically balanced on Jack 1 4 female INPUT B LINE input unbalanced PinR...

Page 8: ...hed Telephone Network analog telephone lines Automatic line compensation is featured TEL PHONE socket allows the connection on parallel of a external telephone set f i for dialling services Please not...

Page 9: ...PinRca connector Out 3 an unbalanced fixed level on PinRca connector Fixed and two Mono outputs summing the left and right channels and dropping the level by 6dB All the Master outputs provide the sam...

Page 10: ...come from the factory with Muting facility associated to Slider opening on Channel 1 On request this facility may be extended to Input channels 2 and 3 too by means of regular slider replacement ref...

Page 11: ...tion to the centre detented position when not required MASTER The input channel signal may be routed to the main Stereo MIX MASTER L R by pressing the Master switch There is a green LED inside which w...

Page 12: ...o MIX MASTER L R by pressing the Master switch There is a green LED inside which will illuminate accordingly PFL Stereo pre fade listening PFL button operated only in latched mode allows pre fade list...

Page 13: ...eard also by the other telephone caller MASTER it connects the telephone output to the Master output The LED inside the button turns on accordingly PFL Pre fade listening PFL button operated only in l...

Page 14: ...10 1 ALIGNEMENT OF INPUTS When plugging in a new source start with the fader turned down and the PFL activated The signal is displayed on the meters on the left hand PFL and can be checked in the head...

Page 15: ...by turning the DEPTH potentiometer in position 10 THR ESHOLD the trimmer inside the hole adjusts the threshold intervention level of the compressor use a small screw driver in order not to damage the...

Page 16: ...will reproduce the EXTERNAL Input signal f i a tuner EXT IN depressed MASTER pressed Monitor speakers headphones will reproduce the MASTER signal EXT IN depressed MASTER depressed Monitor speakers hea...

Page 17: ...llowed A short cable with a 9 pins subD plug on each end male and female comes with the console It is used to connect the meterbridge to the mixer The RIGHT pair of meters always display the Master si...

Page 18: ...D RECEIVE separ 20 dB it can vary depending on telephone line characteristics In out level on tel line 6 dBm on 600 Ohm line imped Compensation mode Electronic automatic Line connection 2 wire RJ11 co...

Page 19: ...on 2 wire RJ11 connector REC Tel output Unbal PinRCA 0 dB level MASTER MODULE MASTER Output 1 2 Stereo El Bal SubD 15P inf to 6 dB control MASTER Output 3 and Fixed Stereo Unbal PinRCA inf to 6 dB con...

Reviews: