11.5 Global Settings
In the global setting screen you can make all kinds of basic settings.
Figure 27.05: Global Settings
Clock Source
Clock source lets you choose the clock to which you want to
synchronize the Oxygen 4 Digital. You can choose the following sources.
-
32 kHz internal
-
44.1 kHz internal
-
48 kHz internal
-
Extern
-
48 kHz Cobranet
The clock frequency chosen is also the clock which is on the Word-clock OUT.
Note: If you are using Cobranet you have to select 48 kHz Cobranet
clock. If not the Cobranet input selections menu options will be
disabled.
Digital Nominal Level
Lets you adjust the headroom for the digital outputs. See also chapter 6.
Auto CUE Reset
This option resets the CUE when a channel goes on air. When this option is
enabled you need to set per channel if you want a local or a total CUE reset.
CUE to CRM
When this option is set the CUE buss will automatically be routed to
the CRM buss when the CUE is activated on a channel.
CRM interlock
If this option is enabled you can only route one buss at a time to the
CRM buss.