5.2 Global configuration
Some overall system settings can be filled in on this webpage.
Figure 6: Global configuration
•
Sample rate
You can select a sample rate of 32 kHz, 44.1 kHz en 48kHz. According to this setting, the
filters are setup so you have to make sure to select the sample rate you work with. Also when
using external clock.
•
Extern(al) clock
If you want to use the external clock (Frame clock in) you can turn it on here.
•
Headroom
The internal headroom is fixed at 20 dB, to adjust the headroom on a local input/output you
can give an offset level to the sources/destinations or at the rack configuration.
•
Fader top level
You can make the fader work with or without 10 dB fader reserve. In the last situation the
faders will be 0 dB (unity gain) when the fader is fully up (maximum position).
•
Auto momentary
Most switch functions can work in a auto-momentary mode. When set to yes a knob will
function latching when pressed shortly. But with a long press (>750 mS) the knob reacts like a
momentary switch (function active while pressed).
•
Startup state
Here you can select to use a known startup state which is the ‘programmed defaults’ or use a
‘backup of the last situation’.
Programmed defaults are the defaults as setup in the web-configuration. An backup of the
console is saved once a minute, which means you will return to (almost) the last situation.