Oxygen 5 Digital - User Manual
Version 2.5 - 12/22/2010
Axel Technology srl
www.axeltechnology.com
|
Patch panels
93
9.2 Wiring
9.2.1 GPIO/Remote
The remote jack connects to all kinds of remote in-/outputs. Such as remote start/stop, external red
lights or cough. The function of the remote jack depends on the I/O card and function setup for this
GPIO. The software determines its function and where it is connected to.
! NEVER CONNECT HIGH POWER VOLTAGE (WALL POWER) TO THE REMOTE-JACK !
If the GPIO jumper setting on the Oxygen 5 Digital-Rack-Board is set for GPO the remote becomes
only a Remote-Output by a build in Solid State Relay. The relay is situated between Tip and Ring of
the
remote
jack.
Normally the GPIO jumper setting on the Oxygen 5 Digital-Rack-boards are set for GPO.
Jack
Name function
Comment
Tip
GP-CC
GPIO Jumper 23 & 56:
Photo MOS relay (max 50V, 200mA)
Ring
GP-NO
Slave
Shield
Ground
Table : GPO Patch Panel w iring
If the GPIO jumper setting on the Oxygen 5 Digital-rack-Board is set for GPIO the remote becomes a
Remote-Output GPO (+5V TTL) on the Tip of the remote jack and a Remote-Input GPI (+5V TTL
internal pull-up) on the Ring. The Sleeve is Shield and the ground for the TTL signal.
Jack
Name function
Comment
Tip
GP-Output
GPIO Jumper 12 & 45:
GPO: +5V, 560R Ohm
GPI:
max. +5V with 10k internal pull-up.
Ring
GP-Input
Slave
Shield
Ground
Table : GPIO Patch Panel w iring
GPIO connection example for MicOn-LED and cough-switch remote.
GPIO connection example for OnAir-Lamp and TB-Sw itch remote.