Oxygen 5 Digital - User Manual
Version 2.5 - 12/22/2010
Axel Technology srl
www.axeltechnology.com
|
Patch panels
94
GPO connection example for remote START Pioneer CD-player.
9.2.2 MIC
The MIC input connects microphones to the Oxygen 5 Digital. The Oxygen 5 Digital Mic Rack Module
supports 48 volts DC phantom power if it is switched on in the software.
Female XLR
Pin
Function
Comment
2
+Audio
Audio in phase
3
–Audio
Audio out phase
1
Shield
Ground
Table 9-1: MIC patch panel XLR wiring
9.2.3 Phones
The Phones jacks connect headphones to the Oxygen 5 Digital console. The PHONES-A and
PHONES-B female jack outputs all carry a stereo headphones signal. The phones connection
connects to the CRM-DA module.
Jack
Name
Function
Tip
Audio left
Ring
Audio right
Slave
Shield
Table 9-2: Phones patch panel jack wiring