Maintenance
CAUTION!! Please be aware that the equipment may, during certain
conditions become very warm and can cause minor injuries if handled
without any protection, such as gloves.
CAUTION!! Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to local laws and instructions.
9.1
General
The system normally operates without any operator intervention or maintenance. If in the
unlikely event of any unit failure, the faulty repeater should be replaced. A failed unit can be
removed and replaced with a spare while the rest of the system (other repeaters) is still
operating. However, the power supply of the failed repeater should be isolated from the
power before anything is replaced.
In the event of a malfunction in the system, the status of the antenna systems as well as the
continuity of the cabling should be checked before replacing any modules within the
repeater.
9.2
Preventative Maintenance
The repeater does not require preventative maintenance apart from changing the battery
once every three years.
9.3
Component Replacement
Except for the backup battery
, none of the modules in the repeater can be replaced without
removing the repeater from its mounting and opening the cover of the repeater.
9.4
Product Disposal
Disposal of this product must be handled according to all national laws and regulations. For
detailed information regarding materials, please refer to Axell Wireless.
9.5
Replacing Backup Battery
NOTE: The backup battery should be replaced every five years. Contact your Axell service
representative for specifications of the replacement battery.
The image below shows the location of the various power elements. These are described in
detail in the following sections.
Figure 9-1. Power Elements Inside Repeater
Backup battery
pack
Battery (BATT) ON/OFF
switch