Mounting

Above the door controller there shall be a minimum space of 40mm.

CPU module

Door controller with integrated network switch, rotary switches for node address

and display with keys for settings and system information.

Node addresses

Door controllers in VAKA systems without B60 should have unique node

addresses from 1 to 10. Door controllers in VAKA systems with B60 should have

unique node addresses from 1 to 50.

The default IP address of the door controller is related to the node address. Node

address 01 will result in a default IP-address of 10.0.0.201, and a node address 04

will result in 10.0.0.204 as the default IP-address.

The node address is set by the rotary switches and should be

set before the door controller is installed in VAKA.

3 (5)

Manual (En) B28

Summary of Contents for Vaka B28

Page 1: ...215 120 23 Stockholm Sweden 46 0 8 722 34 40 info axema se www axema se Door contoller VAKA B28 B28 supports one door with up to two modules day and night locking entry phone and readers in a VAKA system Manual En Updated 2019 05 09 ...

Page 2: ...Door contoller VAKA B28 Mounting 3 CPU module 3 Node addresses 3 VAKA Terminals 4 Termination 4 Technical Data 5 2 5 Manual En B28 ...

Page 3: ... should have unique node addresses from 1 to 10 Door controllers in VAKA systems with B60 should have unique node addresses from 1 to 50 The default IP address of the door controller is related to the node address Node address 01 will result in a default IP address of 10 0 0 201 and a node address 04 will result in 10 0 0 204 as the default IP address The node address is set by the rotary switches...

Page 4: ...ual 12 15 Configurable inputs 2 pcs 16 17 Voltage out Same as voltage across terminal 1 and 2 18 19 Motor lock output Potential free normally open contact 20 21 Bolt monitoring to indicate locked unlocked door 21 22 Door monitoring to indicate open closed door 23 24 Warning relay Activates if the door is not closed after the opening time 25 26 Alert relay Activates if the door is not closed after ...

Page 5: ...B28 Power Supply 12 35VAC 12 40VDC or PoE IEEE 802 1 at Built in switch Yes Built in firewall No PoE support Yes Maximum load relay 1 A 30 VDC IP classification IP22 IK classification IK06 Temperature 0 to 55 C 5 5 Manual En B28 ...

Reviews: