5: E
le
m
en
t O
pe
ra
tio
ns •
82
©2016 Axia Audio- Rev 1.8.1
Meter Peaks
can be hidden or viewed by selecting
Show
or
Hide
as desired.
PGM 3
meter source options are:
»
Program 3
- default
»
Record
(Program 4; post-fade, pre on/off)
»
Phone
(Program 4; pre-fade, pre on/off)
»
External 1
»
External 2
Figure 5-17: Standard Meter Options Menu.
Note: The 2-Fader Monitor module does not
have a Meter Options key. To enter the Meter
Options screen, simply press the Monitor Op-
tions button twice. The first press will give you
Monitor Options; the second press will take you
to Meter Options described below. In addition to
Meter Options, you will also find the global set-
tings for AUX SENDS and AUX RETURNS.
Figure 5-18: 2-Fader Meter Options menu screen.
Meter Ballistics
permits the selection of various
international metering standards. Those selections are:
meter options are:
»
Full Scale VU
- Element default North Ameri-
can style VU meters.
»
BBC Type PPM
»
DIN Type PPM
»
EBU Digital
»
Nordic Type
Figure 5-19 illustrates the 5 different types of meters
and a comparison of these meters displaying a steady
tone with an RMS level 20 dB below digital full scale.
More Meters
will open up an additional meter dis-
play that replaces the centre clock section on the Ele-
ment display. These six meters can be configured to
display any other sources you have specified in the
Monitor section of your Show Profile (see Chapter 6
for details). To close the “More Meters” display, press
the
Meter Options
button twice.
More Meters
is toggled on/off on the 2-Fader Moni-