background image

 IX. Recommended Spare Parts 

Problem 

Cause 

Corrective Action 

Load does not rotate.  

 

Drive air spring not engaged.  

Flip drive air-spring actuator 
switch. 
Check that actuator valve is 
shifting. 

Load is too heavy. 

Try lighter load. 

Fuse is blown. 

Replace fuse. 

Scale indicator not working. 

 

Bad indicator. 

Replace indicator. 

Fuse is blown. 

Replace fuse. 

Scale inaccurately reading. 

 

Scale is not calibrated correctly.  Calibrate per scale manufac-

turer’s manual  

Off-center load. 

Reposition the load. 

Bad load cell. 

Contact scale manufacturer 

for solution. 

 VIII. Troubleshooting 

Quantity 

Description 

Part Number 

1  

Turntable mechanical bearing 

BRGKD0001 

1

 

Remote pendant 

PEN0054 

1

 

Electric motor 

EMTRLE0004 

1

 

Electric 15-amp fuse 

EFUELT0015 

1

 

Scale digital indicator 

ENCBCS0001 

1

 

Drive wheel 

WHL0023C 

1

 

Air spring pilot valve 

VMC-56C53RA 

To reorder a part, please call 

1-800-888-0018 

and ask for the Parts Department.  

If possible, please have your Axial serial number handy for reference.  

Standard Operating Manual 

AX030-0090-MANUAL | 8 

Summary of Contents for AX030-0090

Page 1: ...ADDRESS 2230 Brush College Road Decatur IL 62526 Phone 217 423 6001 Fax 217 422 1049 E mail sales alignprod com Standard Operating Manual AX030 0090 Turntable www AxialIndustrialTurntables com...

Page 2: ......

Page 3: ...Important Precautions 4 II Description of Equipment 4 III Installation and Start Up 5 IV Specifications 6 V Air Supply 6 VI Operation 6 VII Maintenance 7 VIII Troubleshooting 8 IX Recommended Spare P...

Page 4: ...ols or other obstructions Never alter the equipment in any way unless authorized by a qualified Axial Align Production Systems employee II Description of Equipment This equipment consists of a 7 5 ft...

Page 5: ...cells In order to do this lift the turntable top using the 3 10 lifting eyes around the perimeter of the table top This will lift the table bearing and scale top You only need to lift these as little...

Page 6: ...into the wall outlet 120V you should have power to the digital indicator as shown below and your drive motor should have power The air spring actuator switch will engage disengage the drive wheel air...

Page 7: ...attempt to rotate table from both the remote pendant switch and the control stand at the same time VII Maintenance How to Gain Access to Components Using the exploded view below the stack up of compo...

Page 8: ...rate per scale manufac turer s manual Off center load Reposition the load Bad load cell Contact scale manufacturer for solution VIII Troubleshooting Quantity Description Part Number 1 Turntablemechani...

Page 9: ...expense for inspections removal or reinstallation of components or products This warranty does not cover among other things damages resulting from foreign matter or water negligence accident unreasona...

Page 10: ......

Reviews: