background image

Page 17 of 24

Axicon Auto ID Limited | PV-1000 operating manual | January 2022

www.axicon.com

Barcode symbologies checked:

EAN-8, EAN-13, EAN-13+2, EAN13+5, UPC-A, UPC-E, Code 39, Code 93, Code 128, 

GS1-128, GS1 DataBar (both linear and stacked).

Technical specifications

Power

Four AA-sized batteries, of at least 

2500 mAh output – Alkaline or re-

chargeable (rechargeable batteries 

must be charged externally)

Size

Display Box: 180 x 95 x 40mm 

(7.2” x 3.8” x 1.6”)

Weight

650 gms (23oz) incl. batteries

Operating temperature

0ºC to 50ºC

Storage temperature

-20ºC to 70ºC

Humidity

5% to 95% RH non condensing

Regulatory approvals

CE approval (see certificates below for 

full specification)

© Copyright information 

The Axicon software embedded in the PV-1000 together with any accompanying 

Axicon software is the copyright of Axicon Auto ID Ltd and is subject to the software 

licence described below. 

This manual is copyright to Axicon Auto ID Ltd and may not be reproduced in whole 

or in part, nor may it be stored in any electronic storage or retrieval system without 

the express permission in writing from a director of Axicon Auto ID Ltd.

Acknowledgement is made of the relevant copyrights of Microsoft, Word, and 

Notepad referenced in this document.

Summary of Contents for PV-1000

Page 1: ...BARCODE EXPERTS Church Road Weston on the Green Oxfordshire OX25 3QP UK Tel 44 0 1869 351155 Email sales axicon com Web www axicon com operating manual Axicon PV 1000 portable display unit Industry Partner ...

Page 2: ...Page 2 of 24 Axicon Auto ID Limited PV 1000 operating manual January 2022 www axicon com ...

Page 3: ...ation 4 Introduction 5 Getting started 6 Calibration 7 Using the PV 1000 8 Configuration set up 11 ISO IEC or ANSI grades 13 Menu screen formats 14 Frequently asked questions 15 Technical specifications 17 Software licence agreement 18 Axicon warranty 20 Declaration of ISO IEC 21 Declaration of CE 23 Contact us 24 ...

Page 4: ...uld be handled with care Only use accessories supplied or approved by Axicon Use of non approved accessories will invalidate the warranty If the verifier read head is dropped or subjected to similar misuse the accuracy of the results may be affected The unit should be returned to Axicon immediately for servicing Axicon recommends that for optimum accuracy all verifier read heads should be returned...

Page 5: ...1000 operating manual January 2022 www axicon com Introduction What is in the case The PV 1000 ISO ANSI portable display unit Documentation wallet containing the operating manual A set of four AA sized alkaline batteries supplied in UK only ...

Page 6: ...g will be displayed on the screen for about 15 seconds This is the power up and initialisation phase The PV 1000 will show an initialising message before showing the message Axicon Verifier Ready to Scan If the PV 1000 is left for some time the screen will go blank to conserve battery power but can quickly be restarted by pressing the on off button again The time out period before this happens can...

Page 7: ...reen will display Set RMax message with a 85 below Look at your calibration card to find the value for RMax Press Menu Select and you can change the value by using the Scroll up and Scroll down buttons until it matches the value shown on the calibration card Press Menu Select to confirm the setting Press the Scroll down button and the message will be displayed Calibrate press the Menu Select butto...

Page 8: ... barcode Multi scan averaging The PV 1000 allows you to take up to 10 scans of a barcode at different points throughout the height of the barcode which will be averaged automatically to grade the barcode This is the process defined by ISO IEC 15416 To do this simply use the Menu Select button and you will see the message Information Use the Scroll Down button until you see the message Setup Press ...

Page 9: ...sing the optional Axicon printer lead Verify the barcode Press the Print button the screen will show Print Press the Menu Select button The screen will display the message Printing and shortly afterwards the message Done Press the Clear Back button to return to the main screen Please note that this is a unidirectional signal transfer if the printer is not connected properly or not switched on then...

Page 10: ...lug in a USB memory device From the main screen press the Menu Select button and you will see the message Information Press Menu Select and the screen will display Show Code Press Scroll down until the message Transfer is displayed Press Menu Select The message Transferring will be displayed followed by the message Transfer Successful The text file printout will be in a directory named Scans on th...

Page 11: ...until the correct time zone is shown and then press Menu Select to lock the data Use the Scroll Down button and Time will be displayed Press Menu Select Use the Scroll up and Scroll Down buttons until the correct time is shown and then press Menu Select to lock the data Use the Scroll Down button and Date will be displayed Press Menu Select Use the Scroll up and Scroll Down buttons until the corre...

Page 12: ... before Sleep mode is enabled is higher than the number of minutes before Power Down mode then Power Down will occur first Note that 0 Zero minutes means that the sleep mode will be disabled Press Clear Back twice to move back to the main screen To set the Power Off option On the main screen press the Menu Select button to see the message Information Use the Scroll Down button until Setup is displ...

Page 13: ... or F the ANSI approach the format can be changed as explained below To set the ANSI standard display On the main screen press the Menu Select button to see the message Information Use the Scroll Down button until Setup is displayed Press Menu Select Press the Scroll Down button until the screen displays the message Show ANSI is displayed Press Menu Select The screen will display Show ANSI Use the...

Page 14: ... axicon com Menu screen formats Menu level 1 Menu level 2 Menu level 3 Information Show code Encodation Transfer Calibrate Set Rmin Set Rmax Calibrate Setup Average No Pass grade Units Language Autosave Show ANSI Time Time zone Time Date Power Sleep Power off Printer Trailing LF ...

Page 15: ...itself The power management options Sleep and Power Off need to be adjusted as explained on page 12 to meet your requirements If both of these are set to 0 the PV 1000 will stay on continuously Will the PV 1072 read head work with the PV 1000 The PV 1072 read head can only be used with the PV 1072 display unit How long will a set of batteries last In tests with the PV 1000 remaining continuously o...

Page 16: ...V 1000 Switch off the verifier Switch on the verifier and let it initialise Press Menu Select once Press Scroll down twice Press Menu Select once you will see a number on the second line of the display which is the averaging number Press Scroll down three times Press Menu Select once Use the Scroll up and scroll down buttons until the chosen language is shown on the second line of the display Pres...

Page 17: ...ºC Storage temperature 20ºC to 70ºC Humidity 5 to 95 RH non condensing Regulatory approvals CE approval see certificates below for full specification Copyright information The Axicon software embedded in the PV 1000 together with any accompanying Axicon software is the copyright of Axicon Auto ID Ltd and is subject to the software licence described below This manual is copyright to Axicon Auto ID ...

Page 18: ...executing or displaying the software You may not modify the software or disable any licensing or control features of the software Ownership The software is owned and copyrighted by Axicon Auto ID Limited Your licence confers no title or ownership in the software and is not a sale of rights in the software Copies You may not make copies of the software for any purpose whatsoever You may not copy th...

Page 19: ...owever since we have no control over the circumstances in which you might use the display unit you must satisfy yourself that its performance is suitable for your needs Neither Axicon Auto ID Limited nor the vendor of this display unit can accept any liability for any loss or damage consequential or otherwise which may be caused by its use If the display unit or any part of it is defective in any ...

Page 20: ...he original transit case Axicon will automatically charge an additional sum for the replacement of this packaging Axicon reserves the right to charge an inspection fee for any equipment returned under warranty for which no fault is found Please contact Axicon to obtain an RMA return to manufacturer authorisation number before returning any equipment This number must be quoted on all documentation ...

Page 21: ...y test specification ISO IEC 15420 EAN UPC bar code symbology specification ISO IEC 16388 Code 39 bar code symbology specification ISO IEC 16390 Interleaved 2 of 5 bar code symbology specification ISO IEC 15417 Code 128 bar code symbology specification ISO IEC 24724 GS1 DataBar bar code symbology specification We also certify that this equipment conforms to ISO IEC 15426 1 barcode verifier conform...

Page 22: ...www axicon com Page 22 of 24 Axicon Auto ID Limited PV 1000 operating manual January 2022 ...

Page 23: ... Barcoding ISO IEC 15426 European Safety EN 60950 Electromagnetic Compatibility EN 55022 EN 55024 We also certify that the standard EN 60825 is not applicable to the product This equipment meets the requirements of the directives 2004 108 EC Electromagnetic Compatibility 2006 95 EC Low Voltage based on our own relevant test reports Martin Morrison Managing Director Church Road Weston on the Green ...

Page 24: ...0 1869 351 155 Fax 44 0 1869 351 205 Email info axicon com Website www axicon com As Axicon continually improves its products their specifications and features are subject to change without notice All trademarks are acknowledged as belonging to their respective companies Your Axicon distributor ...

Reviews: