Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EEA contact address
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
State of the art 2018-10-08
Technical improvements, changes in design, printing- and other errors expected.
Safety advices:
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
Use only the plug-in power supply unit included in the delivery scope!
By no means is it allowed to replace any parts of the power supply unit
or to make modifications. Otherwise, there is a risk of mortal injury for
which we cannot be held liable.
Providing that a serviceable fuse exists, the power cord must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
The equipment may only be operated in dry rooms. In humid rooms
or outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. Power feeding cables as well as feeder lines may not
be damaged or clamped by objects of any kind. To prevent damage to
your equipment and to avoid possible peripheral damages, the devices
foreseen for wall mounting may only be installed on a flat surface.
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous
air circulation around the equipment. In this way you avoid possible
damage to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
AVM 3-00
basic
-line
TWIN audio/video
modulator
Operation instructions
Technical data:
Article
AVM 3-00
Frequency range
470…862 MHz
Transmission norm
PAL BG / PAL I / SECAM L
Through gain
2...4 dB
Output level, adjustable
70…90 dBµV
RF output impedance
75 Ohm
Video input impedance
75 Ohm
Audio input impedance
10 kOhm
Video input level
1 V
SS
Audio input level
1 V
SS
RF connectors
F-female
Connectors Audio/video
RCA/Cinch + SCART
Power supply
230 V~ 50 Hz/3W
6V=/500 mA
Dimensions (W × H × D) appr.
190 x 170 x 40 mm
Herewith AXING AG declares that the marked products comply with the valid
guidelines. You can call up the complete EU declaration of conformity for
download by entering the article in the search field at www.axing.com.
WEEE Nr. DE26869279 | Electrical and electronic components must not be