3.7. Devices
Sign in EOC 20-01 and open ‘
Devices
’ window.
Each row represents an EoC 20-0x. The figure shows the following example:
∂
An EoC 20-01 master
∂
Two EoC 20-02 endpoints
Click on ‘
Refresh
’ button will scan all connected devices status again, new on-line EP may take time to
appear in the window.
For each shown column:
No:
EP index number.
Sel:
click on ‘Sel’ button will select all listed on-line EPs at once for EP operation – Upgrade EoC/
Upgrade WiFi/ ReConfig, or just designate the EP one by one for EP operation – Upgrade EoC/
Upgrade WiFi/ ReConfig. The top row is the local Master device.
PE(Up/Dn): Per EP Upstream/Downstream payload encoding, the running carrier speed.
Link:
light for EoC device current link status.
Green:
EP is active – on-line. For Master device, Green always unless Master’s EoC driver is broken.
Yellow:
EP is active – in-configuring. EOC 20-01 NMU is initializing the EP, turns to Green while the EP
initialization has been completed.
Red:
EP is active – unrecognized, and cannot be configured by EOC 20-01 NMU.
Gray:
EP is not active – off-line, either user powers it off or cabling has trouble.
MAC:
EoC
MAC
address.
Model:
the current queried EoC EP model name
Driver:
the current queried working (running) EoC Master or EP driver version.
WiFi:
the current queried working (running) EP WiFi driver version.
Note:
used to denote Master for EoC coax network; to denote EP end-user for recording info like user
name or address.