background image

 

Observe the safety instructions supplied with the device!
They are also available at the following Internet address:

https://download.axing.com/BAs/Sicherheitshinweise_9sprachig.pdf

 

Use the device only as described in these operating instructions and in 
particular in accordance with the state of the art. 
If the device is used for other purposes, no warranty will be assumed!

Page 1 of 2 | AXING-BA_BVS-20-xx | 2022-11-24

Technical improvements, changes in design, printing and other errors reserved.

Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

EU Declaration of Conformity

Hereby AXING AG declares that the CE marked products comply with the 

valid EU guidelines.

WEEE Nr. DE26869279 | Electrical and electronic components must not be 

disposed of as residual waste, it must be disposed of separately.

BVS 20-00
BVS 20-46 | BVS 20-47

premium

-line

CATV amplifiers

Operation instructions

Technical data

Type

BVS 20-00

BVS 20-46

BVS 20-47

EMC

according to EN 50083-2, class A

Downstream

Frequency range

85…1006 MHz

47/ 85*... 

1006 MHz

47/ 85*... 

1006 MHz

Gain

36 dB

30 dB

36 dB

Max. output level CSO/CTB 
(CENELEC raster, 41 channels, 60 dB IMA)

107 dBµV

Attenuation: adjustable in 1 dB steps

0…15 dB

Equalization: adjustable in 1 dB steps

0…15 dB

Attenuation interstage: pluggable with 
jumpers

0 | 2 | 4 | 6 dB

Equalization interstage: pluggable with 
jumpers

0 | 2 | 4 | 6 dB

Return loss

≥ 18 dB (-1,5 dB/Octave)

Noise figure typ.

≤ 6,5 dB

RF connectors

Type

F-female

Test port at in-/output

-20 ±2,5 dB/-20 ±1,0 dB

General

Switching power supply

100...240 VAC / 50...60 Hz

Power indicator

LED

Power consumption

8 W 

Equipotential bonding connection

4 mm²

Operating temperature range 
(acc. to EN 60065)

-20…+50°C

Dimensions (W × H × D) appr.

195 × 90 × 55 mm

Weight

0,480 kg

Protection class

IP 54