background image

Page 2 of 2 | AXING-BA_BVS-20-xx | 2022-11-24

Field of application

The devices are suited only for amplifying radio, television and DOCSIS signals 
in the house! If the device is used for other purposes, no warranty is given!

Equipotential bonding and Mounting

To avoid dangerous overvoltages (attention: risk of fire/death), the devices 
must be connected to the equipotential bonding according to EN 60728-11.

 

Use the equipotential bonding connection attached to the device (3).

 

To connect the outer conductor of the coaxial cable to the equipotential 
bonding, use e.g. earth connection blocks CFA or earthing angles QEW at 
the input and output of the amplifier. 

 

Use the mounting screws included in the delivery and the mounting holes 
of the devices (4).

RF Installation

 

Connect the input of the amplifier to the interconnection point. Connect the 
output of the amplifier to your house distribution.

 

Use a highly shielded coaxial cable with an F connector. Suitable cables and 
connectors can be found in the current AXING catalogue or under www.
axing.com.

 

The test ports at the input is bi-directional. This test point has to be activa-
ted or deactivated with the adjacent jumper.

4

4

3

Adjustments of gain and slope

 

The jumpers (7 and 8) are used to adjust the interstage attenuation and 
slope in the forward frequency range.

 

Adjust the gain and the slope with the PCB sitches (5 and 6) in the 
forward frequency range.

Return path modules

For the amplifiers there are return path modules (BZU 20-xx) available.

 

Before inserting the return channel module, the 4 DIP switches (see 9 in 
above drawing) must be set to the OFF.

 

When the RC module is removed again, the 4 DIP switches must be set 
to the ON position again. This is the only way to guarantee troublefree 
operation. 

Note:

 If return path modules with 5...65 MHz are used, VHF/band I in 

forward path is not possible.

BSD 963-11N

BSD 963-12N

BSD 963-17N

QEW 5-50

BVE 4-02P

TV

CMO 2-01

BVS 20-47

Koax
Coax
Up- und Downstream (Koax)
Up- and Downstream (Coax)
Potentialausgleich
Equipotential bonding

HÜP

IP

85MHz

47MHz

85MHz gesteckt = mit Rückkanalmodul
47MHz gesteckt = ohne Rückkanalmodul

5

6

7

8

9 9

Power indicator LED

The amplifier comes with LED (POWER) which shows the operation mode:

 

9

green = in operation 

 

9

out = no power supply