Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EEA contact address
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
State of the art 2019-12-04
Technical improvements, changes in design, printing- and other errors expected.
Safety advices:
The device may only be installed and put into operation by personnel
who have received the necessary training on handling optical and
electrical devices and who have been instructed on safety instructions
for handling lasers.
Installation and repairs to the equipment may only be carried out by
technicians observing the current guidelines. No liability will be assumed
in the case of faulty installation and commissioning.
Before handling or opening the equipment pull out the power plug or
remove the power supply, otherwise there is danger of electrocution. This
is also valid for cleaning the equipment or working on the connections.
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
Providing that a serviceable fuse exists, the power cord must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
The equipment may only be operated in dry rooms. In humid rooms
or outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
Choose a location of installation or mounting which complies to the
protection class IP 54.
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. Power feeding cables as well as feeder lines may not
be damaged or clamped.
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators, other electrical devices, chimneys, etc.).
Devices that are equipped with heat sinks or ventilation slots must under
no circum-stances be covered or blocked. Also ensure for a generous
air circulation around the equipment. In this way you avoid possible
damage to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimneys, etc.).
ONX 1550-01
premium
-line
Micro Fibre Node
Operation instructions
Technical data:
Herewith AXING AG declares that the marked products comply with the valid
guidelines.
WEEE Nr. DE26869279 | Electrical and electronic components must not be
disposed of as residual waste, it must be disposed of separately.
Type
ONX155001
Input
Optical connector
1 × SC/APC
Optical return loss
≥ 40 dB
Downstream
Wavelength
1540...1560 nm
Optical input level
-8…+1 dBm
Optical OLC range
0…-6 dBm
Frequency range
85…1218 MHz
Output level @ OMI 3.5% (flat)
94 dBµV
CSO (Cenelec 42, OMI 3.5%)
60 dBc
CTB (Cenelec 42, OMI 3.5%)
60 dBc
Flatness
±1 dB
Noise current density
7,4 pA/√Hz
Equalization interstage: pluggable with jumpers
0/2/4/6 dB
Return loss
≥ 18 dB (-1,5 dB/octave)
Test port
-20 dB
Upstream
Laser type
DFB
Wavelength
1310 nm
Laser mode (switchable)
CW/Burst
Optical output level
+3 ±1 dBm
Laser switch-on time
≤ 1.3 µsec
RF level for laser on | off
67 dBµV | 58 dBµV
Frequency range
5…65 MHz
Flatness
±1 dB
Return loss
≥ 18 dB (-1,5 dB/octave)
Attenuation: adjustable in 2 dB steps
0…30 dB
Test port
-20 dB
RF connectors
Type
F-female
General
Operation voltage
100...240 VAC
Power consumption
6 W
Operating temperature range
0...50 °C
Dimensions (W × H × D) appr.
195 x 90 x 55 mm