background image

Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

State of the art 2019-12-04

Technical improvements, changes in design, printing- and other errors expected.

Safety advices:

 

The device may only be installed and put into operation by personnel 
who have received the necessary training on handling optical and 
electrical devices and who have been instructed on safety instructions 
for handling lasers. 

 

Installation and repairs to the equipment may only be carried out by 
technicians observing the current guidelines. No liability will be assumed 
in the case of faulty installation and commissioning.

 

Before handling or opening the equipment pull out the power plug or 
remove the power supply, otherwise there is danger of electrocution. This 
is also valid for cleaning the equipment or working on the connections. 

 

Only use the mains cable connected to the device. Never replace any 
parts or make any modifications on the mains cable. Otherwise there is a 
risk of mortal injury for which we cannot be held liable.

 

Providing that a serviceable fuse exists, the power cord must be pulled 
out before changing the fuse. Defective fuses may only be replaced with 
standard compliant fuses that have the same nominal value.

 

The equipment may only be operated in dry rooms. In humid rooms 
or outdoors there is danger of short-circuit (caution: risk of fire) or 
electrocution.

 

Choose a location of installation or mounting which complies to the 
protection class IP 54.

 

Choose the location of installation or mounting so that the power plug 
can be reached and pulled out of the socket easily in case of danger. 
Choose the location of installation or mounting such that children may 
not play unsupervised near the equipment and its connections. The 
location of installation or mounting must allow a safe installation of all 
cables connected. Power feeding cables as well as feeder lines may not 
be damaged or clamped.

 

Avoid exposure of the equipment to direct sunlight and to other heat 
sources (e. g. radiators, other electrical devices, chimneys, etc.). 

 

Devices that are equipped with heat sinks or ventilation slots must under 
no circum-stances be covered or blocked. Also ensure for a generous 
air circulation around the equipment. In this way you avoid possible 
damage to the equipment as well as a risk of fire caused by overheating. 
Absolutely avoid that cables come near any source of heat (e.g. 
radioators, other electrical devices, chimneys, etc.).

ONX 1550-01

premium

-line

Micro Fibre Node

Operation instructions

Technical data:

Herewith AXING AG declares that the marked products comply with the valid 

guidelines. 
WEEE Nr. DE26869279 | Electrical and electronic components must not be 

disposed of as residual waste, it must be disposed of separately.

Type

ONX155001

Input

Optical connector

1 × SC/APC

Optical return loss

≥ 40 dB

Downstream

Wavelength

1540...1560 nm

Optical input level

-8…+1 dBm

Optical OLC range

0…-6 dBm

Frequency range

85…1218 MHz

Output level @ OMI 3.5% (flat)

94 dBµV

CSO (Cenelec 42, OMI 3.5%)

60 dBc

CTB (Cenelec 42, OMI 3.5%)

60 dBc

Flatness

±1 dB

Noise current density

7,4 pA/√Hz

Equalization interstage: pluggable with jumpers

0/2/4/6 dB

Return loss

≥ 18 dB (-1,5 dB/octave)

Test port

-20 dB

Upstream

Laser type

DFB

Wavelength

1310 nm

Laser mode (switchable)

CW/Burst

Optical output level

+3 ±1 dBm

Laser switch-on time

≤ 1.3 µsec

RF level for laser on | off

67 dBµV | 58 dBµV

Frequency range

5…65 MHz

Flatness

±1 dB

Return loss

≥ 18 dB (-1,5 dB/octave)

Attenuation: adjustable in 2 dB steps

0…30 dB

Test port

-20 dB

RF connectors

Type

F-female

General

Operation voltage

100...240 VAC

Power consumption

6 W

Operating temperature range

0...50 °C

Dimensions (W × H × D) appr.

195 x 90 x 55 mm

Summary of Contents for premium-line ONX 1550-01

Page 1: ... und dessen Anschlüssen spielen können Der Montage bzw Aufstellort muss eine sichere Verlegung aller angeschlossenen Kabel ermöglichen Stromversorgungskabel sowie Zuführungskabel dürfen nicht beschädigt oder gequetscht werden Setzen Sie das Gerät niemals direkter Sonneneinstrahlung aus und vermeiden Sie die direkte Nähe von Wärrmequellen z B Heizkörper andere Elektrogeräte Kamine etc Bei Geräten d...

Page 2: ...Schutzabdeckung so lange auf der Steckverbindung bleiben bis die Verbindungen hergestellt ist Entfernen Sie die Schutzabdeckung vom Stecker ohne die Ferrule zu berühren Stecken Sie den Stecker anhand der Führungen ein bis er einrastet Um den Stecker wieder zu entfernen drücken Sie auf den Stecker und ziehen Sie das Kabel heraus HF Anschluss Der Micro Fibre Node verfügt über eine F Buchse am Ausgan...

Page 3: ...d near the equipment and its connections The location of installation or mounting must allow a safe installation of all cables connected Power feeding cables as well as feeder lines may not be damaged or clamped Avoid exposure of the equipment to direct sunlight and to other heat sources e g radiators other electrical devices chimneys etc Devices that are equipped with heat sinks or ventilation sl...

Page 4: ...be damaged To protect the contact surfaces of the optical connectors the protectors should be left in position until the connections are made Remove the protective cover from the connector without touching the ferule Insert the connector following the guides until it clicks into place To remove the fibre press the connector and pull out the cable RF installation The Micro Fibre Node has an F socke...

Reviews: