Operation instructions | Serie RFQ-845 and Serie RFO-845
2.1.3.
Power supply in the headend base unit
The power supply units supply the modules with 16 V DC voltage. The current consumption of all connected
modules must not exceed the maximal delivery of the power supply unit used.
The remote power rails at the SAT IF inputs must be added to the current consumption of the modules. The
current consumption at the SAT IF inputs is limited to 250 mA per input. Please take account of the current
consumption of the devices when choosing the LNBs or the multiswitches.
RFT-804 /
RFP-806 (10 A)
RFB-804* /
RFP-806 (10 A)
RFB-804* /
RFP-820 (2×10
A)
RFT-808 /
RFP-808 (18 A)
RFQ-845(CI)
1.5 A + LNB current
consumption
4
4
4
8
RFO-845(CI)
3A + LNB current
consumption
3
3
4
5
*Please note: The RFB-804 is supplied without power supply unit and remote control unit.
2.2.
External operation
Please note that the installation must be carried out on an even and vertical surface.
Any unevenness must be compensated.
Fix the module with 2 screws appropriated for the installation surface.
Install the module in compliance with the safety regulations defined by the EN 60728-11 standard.
Connect the module with an equipotential bonding cable (copper, minimum 4 mm²).
For an operation without a basic unit, the outputs of several modules must be combined with a distributor.