background image

 

SYMBOLS 

 

AC (Alternating Current) 

 

DC (Direct Current) 

 

DC or AC (alternating current or direct current) 

 

Caution, risk of danger, refer to the operating manual before use. 

 

Caution, risk of electric shock 

 

Earth (ground) Terminal 

 

Fuse 

 

Conforms to European Union directives 

 

The equipment is protected throughout by double or reinforced insulation 

 

Diode 

 

Continuity test 

 

Low battery 

LOGIC 

Logic level test 

AUTO 

Autorange 

 

 

 

 

 

 

Summary of Contents for AX-201

Page 1: ...Pen probe style autorange digital multimeter AX 201 Owners manual...

Page 2: ...n b Inspect the test lead for damage insulation or exposed metal Check the test lead and test probe for continuity Replace damage test lead before you use the meter c Do not use the meter if it operat...

Page 3: ...within Measurement Categories III and IV Caution To avoid possible damage to the meter or to the equipment under test follow these guidelines Disconnect circuit power and discharge all capacitors bef...

Page 4: ...tion risk of danger refer to the operating manual before use Caution risk of electric shock Earth ground Terminal Fuse Conforms to European Union directives The equipment is protected throughout by do...

Page 5: ...Rate About 3 times sec Battery 9V 6F22 or equivalent Low Battery Indication show on the display Operating condition 0 40 C relative humidity 75 Storage condition 20 60 C relative humidity 85 Size 230...

Page 6: ...the built0in buzzer sounds INSTRUCTION 1 Display 3 digits LCD with max reading 1999 2 Buton To enable the flashlight function Press and hold down this button 3 Button To hold the present reading on t...

Page 7: ...tions DC voltage AC voltage DC current AC current diode continuity 8 Button To turn on or off the backlight press and hold down this button for about 1 second The backlight will turn off automatically...

Page 8: ...he display show Connect the test probe and the black test lead in series with the circuit to be measured The display will show the reading and the polarity of the test probe connection Note The max pe...

Page 9: ...he function switch to position Press the button to make the display show Connect the test probe to the anode of the diode the black test lead to the cathode of the diode Read the approximate forward v...

Page 10: ...ess the button BATTERY REPLACEMENT When the symbol appears on the display it indicates that the battery is low To replace the battery remove the screw from the battery cover replace the exhausted batt...

Page 11: ...Manual 1 piece DISPOSAL OF THIS ARTICLE Dear Customer If you at some point intend to dispose of this article then please keep in mind that many of its components consist of valuable materials which c...

Reviews: