This button can also be used to arouse the meter from Sleep. 

4.

 

Function Switch 

The switch is used for selecting the desired function. To preserve the battery’s life, set  the switch 
to “OFF” position when the meter is not in use. 

5.

 

Test Probe 

Input probe (positive polarity) for the following teste: voltage, resistance, current (<200mA) and 
diode. 

6.

 

Flashlight LED 

It is used for illumination. 

7.

 

 Button 

This button can be used to switch the meter between the following measurement functions:  
DC voltage/AC voltage; DC current/AC current; diode/continuity. 

8.

 

Button 

To turn on or off the backlight, press and hold down this button for about 1 second. The backlight 
will turn off automatically about 15 seconds later after it is turned on. 

9. Probe of the Black Test Lead (negative) 

10. Black Test Lead 

OPERATION INSTRUCTION 

Measuring DC Voltage 

 

Set the function switch to 

 position,

 

 

Press the 

 button to select DC range, the display shows 

.

 

 

Connect the test probe and black test lead across the source or load to be measured.

 

 

The display will show the reading and the polarity of the test probe connection.

 

Note: 

Input impedance: about 10M

 

The max. permitted input voltage: 600Vdc 

Summary of Contents for AX-201

Page 1: ...Pen probe style autorange digital multimeter AX 201 Owners manual...

Page 2: ...n b Inspect the test lead for damage insulation or exposed metal Check the test lead and test probe for continuity Replace damage test lead before you use the meter c Do not use the meter if it operat...

Page 3: ...within Measurement Categories III and IV Caution To avoid possible damage to the meter or to the equipment under test follow these guidelines Disconnect circuit power and discharge all capacitors bef...

Page 4: ...tion risk of danger refer to the operating manual before use Caution risk of electric shock Earth ground Terminal Fuse Conforms to European Union directives The equipment is protected throughout by do...

Page 5: ...Rate About 3 times sec Battery 9V 6F22 or equivalent Low Battery Indication show on the display Operating condition 0 40 C relative humidity 75 Storage condition 20 60 C relative humidity 85 Size 230...

Page 6: ...the built0in buzzer sounds INSTRUCTION 1 Display 3 digits LCD with max reading 1999 2 Buton To enable the flashlight function Press and hold down this button 3 Button To hold the present reading on t...

Page 7: ...tions DC voltage AC voltage DC current AC current diode continuity 8 Button To turn on or off the backlight press and hold down this button for about 1 second The backlight will turn off automatically...

Page 8: ...he display show Connect the test probe and the black test lead in series with the circuit to be measured The display will show the reading and the polarity of the test probe connection Note The max pe...

Page 9: ...he function switch to position Press the button to make the display show Connect the test probe to the anode of the diode the black test lead to the cathode of the diode Read the approximate forward v...

Page 10: ...ess the button BATTERY REPLACEMENT When the symbol appears on the display it indicates that the battery is low To replace the battery remove the screw from the battery cover replace the exhausted batt...

Page 11: ...Manual 1 piece DISPOSAL OF THIS ARTICLE Dear Customer If you at some point intend to dispose of this article then please keep in mind that many of its components consist of valuable materials which c...