2A / ±(1.5%+10) / 1mA
20A / ±(2.0%+5) / 10mA
Maximum voltage drop measured: Full range mA: 200mV
Maximum input current: 10A (not more than 10s);
Overload protection: 0.2A/250V fuse; 20A/250V fuse.
2.2.5. AC current measurement
Range / Accuracy / Resolution
200mA / ±(1,5%+15) / 100uA
2A / ±(2.0%+5) / 1mA
20A / ±(3.0%+10) / 10mA
Maximum voltage drop measured: 200mV;
Maximum input current: 20A (not more than 15s);
Overload protection: 0.2A/250V fuse; 20A/250V fuse.
Frequency response: (40~200)Hz
Display: Sine wave RMS (Average value response)
2.2.6. Resistance
Range / Accuracy / Resolution
200Ω / ±(0.8%+5) / 0.1Ω
2kΩ / ±(0.8%+3) / 1Ω
20kΩ / ±(0.8%+3) / 10Ω
200kΩ / ±(0.8%+3) / 100Ω
2MΩ / ±(0.8%+3) / 1kΩ
200MΩ / ±(5.0%+20) / 100KΩ
Testing condition: Open voltage is approx. 3V
Over load protection: 250V DC or AC peak value
At range 200Ω, short-circuit the test leads to measure the wire resistance, then subtracts it from the real
measurement.
2.2.7. Capacitance
Range / Accuracy / Resolution
20nF / ±(3,5%+20) / 10pF
200nF / ±(3,5%+20) / 100pF
2uF / ±(3,5%+20) / 1nF
20uF / ±(5,0%+10) / 10nF
200uF / ±(5,0%+10) / 100nF
2000uF / ±(5,0%+10) / 1uF
Overload protection: 36V DC or AC peak value