3.7. Capacitance measurement

• Insert the black multimeter probe into “COM” end, and the red multimeter probe into “VΩHz” end;
• Select the knob to proper capacitance range,
Notes
• If the capacitance under tested is over the max. Value of selected range, LCD displays “OL”, thus should

select the knob to a higher range.

• When measuring at large capacitance range, if capacitor is crept badly or broken, LCD displays a value

and it’s unstable.

• Tested capacitor shall be completely discharged, for fear of damaging the instrument;
• Unit: 1uF=1000nF 1nF=1000pF

3.8. Square Wave Output

• Insert test leads or shielded cable into “COM” and “ V/Ω/Hz” terminal.
• Set the knob to square wave and connect the probe cable to the oscilloscope with test leads, it will

display a value under 50-5kHz.

Notes
• The initial square wave output is 50Hz, if want to output different frequency, press „HOLD” to choose.
• CAUTION: do not input voltage at this range!

3.9. Diode and on-off test

• Insert the black multimeter probe into “COM” hole and red multimeter probe into “VHz” hole (the

polarity of red multimeter pole is “+”;

• Rotate the functional switch to “DIODE” or “BUZZ” level;
• Measurement in forward direction: Connect the red/black multimeter probe to the positive/ negative

pole of the tested diode, and the display unit will display the approximate value of the voltage drop in
forward direction of the diode;

• The buzzer sounds if the resistance of a circuit under test is less than (50±20)Ω.
Notes
• Don’t input voltage at

level.

3.10. Transistor measurement

• Set the knob to hFE range. Inset the test leads to “COM” and “mA” Note: “COM” terminal is for positive

pole (+), “mA” terminals is (-).
Verify the transistor under tested is NPN or PNP, insert emitter, base and collector to proper jack.

Summary of Contents for AX-582B

Page 1: ...o avoid fault operation Please do not measuring before battery isn t installed and back cap isn t firm Do not input any voltage when measure resistance Always remove the test leads before replacing th...

Page 2: ...3 100mV 1000V 1 0 10 1V Input impedance 10M Over load protection 250V DC or AC peak value for range 200mV 1000V DC or AC peak value for other ranges 2 2 3 AC Voltage Measurement Range Accuracy Resolu...

Page 3: ...se Frequency response 40 200 Hz Display Sine wave RMS Average value response 2 2 6 Resistance Range Accuracy Resolution 200 0 8 5 0 1 2k 0 8 3 1 20k 0 8 3 10 200k 0 8 3 100 2M 0 8 3 1k 200M 5 0 20 100...

Page 4: ...is approx 1mA the backward voltage is approx 3V Value displayed Buzzer sounds the resistance is less than 50 20 Testing condition Open voltage is approx 3V Overload protection DC or AC250V peak value...

Page 5: ...3 Application Method 3 1 Description of operating panel 1 LCD unit It displays the numerical value measured with the instrument and its unit 2 1 Power ON OFF 2 2 HOLD B L 2 3 MIN MAX key...

Page 6: ...ut to DC Voltage above 1000V or AC above 750V RMS Never contact the high voltage circuit measured 3 3 AC Voltage Measurement Insert the black multimeter probe into COM end and the red multimeter probe...

Page 7: ...ange and the range switch shall be rotated to a higher level The maximum input current is 200mA or 20A depending on the inserting location of red probe In case of exceeding rated current the fuse will...

Page 8: ...5kHz Notes The initial square wave output is 50Hz if want to output different frequency press HOLD to choose CAUTION do not input voltage at this range 3 9 Diode and on off test Insert the black multi...

Page 9: ...is instrument is precise and users shall never change its circuit at random Protect the instrument from water dust and hurl down Never store or use the instrument in high temperature high humidity fla...

Page 10: ...not connected Holding switch Replace the batteries Appearance of the sign Replace the batteries No input of current Replace the fuse Big error in display Replace the batteries The specifications are s...

Reviews: